Your browser doesn't support javascript.
loading
Three-dimensional image integration guidance for cryoballoon pulmonary vein isolation procedures.
Bourier, Felix; Vlachos, Konstantinos; Lam, Anna; Martin, Claire A; Takigawa, Masateru; Kitamura, Takeshi; Massoullié, Grégoire; Cheniti, Ghassen; Frontera, Antonio; Duchateau, Josselin; Pambrun, Thomas; Klotz, Nicolas; Derval, Nicolas; Denis, Arnaud; Hocini, Mélèze; Haïssaguerre, Michel; Cochet, Hubert; Jaïs, Pierre; Sacher, Frédéric.
Afiliación
  • Bourier F; Electrophysiology and Ablation Unit, Bordeaux University Hospital (CHU), Pessac-Bordeaux, France.
  • Vlachos K; IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France.
  • Lam A; Université de Bordeaux, INSERM U1045, Bordeaux, France.
  • Martin CA; Electrophysiology and Ablation Unit, Bordeaux University Hospital (CHU), Pessac-Bordeaux, France.
  • Takigawa M; IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France.
  • Kitamura T; Université de Bordeaux, INSERM U1045, Bordeaux, France.
  • Massoullié G; Electrophysiology and Ablation Unit, Bordeaux University Hospital (CHU), Pessac-Bordeaux, France.
  • Cheniti G; IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France.
  • Frontera A; Université de Bordeaux, INSERM U1045, Bordeaux, France.
  • Duchateau J; Electrophysiology and Ablation Unit, Bordeaux University Hospital (CHU), Pessac-Bordeaux, France.
  • Pambrun T; IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France.
  • Klotz N; Université de Bordeaux, INSERM U1045, Bordeaux, France.
  • Derval N; Electrophysiology and Ablation Unit, Bordeaux University Hospital (CHU), Pessac-Bordeaux, France.
  • Denis A; IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France.
  • Hocini M; Université de Bordeaux, INSERM U1045, Bordeaux, France.
  • Haïssaguerre M; Electrophysiology and Ablation Unit, Bordeaux University Hospital (CHU), Pessac-Bordeaux, France.
  • Cochet H; IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France.
  • Jaïs P; Université de Bordeaux, INSERM U1045, Bordeaux, France.
  • Sacher F; Electrophysiology and Ablation Unit, Bordeaux University Hospital (CHU), Pessac-Bordeaux, France.
J Cardiovasc Electrophysiol ; 30(12): 2790-2796, 2019 12.
Article en En | MEDLINE | ID: mdl-31646698
ABSTRACT

BACKGROUND:

We present a new, easily applicable approach for the guidance of cryoballoon (CB) pulmonary vein isolation (PVI) procedures that use the combination of a 3D-mapping system image integration module and computed tomographic (CT)-derived anatomy. The aim of this retrospective, nonrandomized study was to investigate (a) an alternative use for an established radiofrequency image integration module for cryo procedures; (b) a guidance technology for cryo PVI based on integrated CT anatomy; and (c) its clinical impact. METHODS AND

RESULTS:

CT left atrium-angiography was performed in 50 consecutive patients before a CB PVI procedure, and a 3D reconstruction of the cardiac anatomy was segmented. A total of 25 patients were treated using conventional fluoroscopy; 25 patients were treated using the 3D image integration technique. In the image integration group, the CARTO3 UNIVU (Biosense Webster) module was used for image integration of 3D anatomy and fluoroscopic imaging. Transseptal puncture and cryo PVI were guided by 3D-overlay imaging. Procedures were feasible without complications in all patients and cryo PVI procedures were successfully guided using the image integration technique. The intraprocedural time needed to perform image integration was 37 ± 10 seconds. Fluoroscopy time was 31.7 ± 11.7 minutes in the conventional group and 20.1 ± 7.9 minutes in the image integration group (P < .001), procedure time was 116.3 ± 29.0 minutes in the conventional group vs 101.2 ± 20.9 minutes in the 3D group (P = .04).

CONCLUSION:

3D-overlay guidance of CB PVI is feasible, safe, and applicable in real time with minimal effort. It may significantly reduce radiation exposure by introducing 3D information, known from electroanatomic mapping systems, into cryo PVI procedures.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Venas Pulmonares / Fibrilación Atrial / Tomografía Computarizada por Rayos X / Criocirugía / Imagenología Tridimensional / Cirugía Asistida por Computador Tipo de estudio: Guideline / Observational_studies / Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Venas Pulmonares / Fibrilación Atrial / Tomografía Computarizada por Rayos X / Criocirugía / Imagenología Tridimensional / Cirugía Asistida por Computador Tipo de estudio: Guideline / Observational_studies / Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Francia
...