Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction.
Liu, Jiaen; van Gelderen, Peter; de Zwart, Jacco A; Duyn, Jeff H.
Afiliación
  • Liu J; Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Dr. BLDG. 10, RM. B1D-723, Bethesda, MD, 20892-1065, USA. Electronic address: jiaen.liu@nih.gov.
  • van Gelderen P; Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Dr. BLDG. 10, RM. B1D-723, Bethesda, MD, 20892-1065, USA.
  • de Zwart JA; Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Dr. BLDG. 10, RM. B1D-723, Bethesda, MD, 20892-1065, USA.
  • Duyn JH; Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Dr. BLDG. 10, RM. B1D-723, Bethesda, MD, 20892-1065, USA.
Neuroimage ; 206: 116332, 2020 02 01.
Article en En | MEDLINE | ID: mdl-31689535
ABSTRACT
T2*-weighted gradient echo (GRE) MRI at high field is uniquely sensitive to the magnetic properties of tissue and allows the study of brain and vascular anatomy at high spatial resolution. However, it is also sensitive to B0 field changes induced by head motion and physiological processes such as the respiratory cycle. Conventional motion correction techniques do not take these field changes into account, and consequently do not fully recover image quality in T2*-weighted MRI. Here, a novel approach was developed to address this by monitoring the B0 field with a volumetric EPI phase navigator. The navigator was acquired at a shorter echo time than that of the (higher resolution) T2*-weighted GRE imaging data and accelerated with parallel imaging for high temporal resolution. At 4 â€‹mm isotropic spatial resolution and 0.54 â€‹s temporal resolution, the accuracy for estimation of rotation and translation was better than 0.2° and 0.1 â€‹mm, respectively. The 10% and 90% percentiles of B0 measurement error using the navigator were -1.8 and 1.5 Hz  at 7 T, respectively. A fast retrospective reconstruction algorithm correcting for both motion and nonlinear B0 changes was also developed. The navigator and reconstruction algorithm were evaluated in correcting motion-corrupted high-resolution T2*-weighted GRE MRI on healthy human subjects at 7 â€‹T. Excellent image quality was demonstrated with the proposed correction method.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Procesamiento de Imagen Asistido por Computador / Encéfalo / Imagen por Resonancia Magnética / Artefactos / Imagenología Tridimensional / Movimiento Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Neuroimage Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Procesamiento de Imagen Asistido por Computador / Encéfalo / Imagen por Resonancia Magnética / Artefactos / Imagenología Tridimensional / Movimiento Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Neuroimage Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2020 Tipo del documento: Article
...