Your browser doesn't support javascript.
loading
A Randomized, Placebo-Controlled Double-Blind Trial of a Closed-Loop Glucagon System for Postbariatric Hypoglycemia.
Mulla, Christopher M; Zavitsanou, Stamatina; Laguna Sanz, Alejandro Jose; Pober, David; Richardson, Lauren; Walcott, Pamela; Arora, Ipsa; Newswanger, Brett; Cummins, Martin J; Prestrelski, Steve J; Doyle, Francis J; Dassau, Eyal; Patti, Mary Elizabeth.
Afiliación
  • Mulla CM; Research Division, Joslin Diabetes Center, Boston, MA.
  • Zavitsanou S; Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA.
  • Laguna Sanz AJ; Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA.
  • Pober D; Research Division, Joslin Diabetes Center, Boston, MA.
  • Richardson L; Research Division, Joslin Diabetes Center, Boston, MA.
  • Walcott P; Research Division, Joslin Diabetes Center, Boston, MA.
  • Arora I; Research Division, Joslin Diabetes Center, Boston, MA.
  • Newswanger B; Xeris Pharmaceuticals, Chicago, IL.
  • Cummins MJ; Xeris Pharmaceuticals, Chicago, IL.
  • Prestrelski SJ; Xeris Pharmaceuticals, Chicago, IL.
  • Doyle FJ; Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA.
  • Dassau E; Research Division, Joslin Diabetes Center, Boston, MA.
  • Patti ME; Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA.
J Clin Endocrinol Metab ; 105(4)2020 04 01.
Article en En | MEDLINE | ID: mdl-31714583
BACKGROUND: Postbariatric hypoglycemia (PBH) can threaten safety and reduce quality of life. Current therapies are incompletely effective. METHODS: Patients with PBH were enrolled in a double-blind, placebo-controlled, crossover trial to evaluate a closed-loop glucose-responsive automated glucagon delivery system designed to reduce severe hypoglycemia. A hypoglycemia detection and mitigation algorithm was embedded in the artificial pancreas system connected to a continuous glucose monitor (CGM, Dexcom) driving a patch infusion pump (Insulet) filled with liquid investigational glucagon (Xeris) or placebo (vehicle). Sensor/plasma glucose responses to mixed meal were assessed during 2 study visits. The system delivered up to 2 doses of study drug (300/150 µg glucagon or equal-volume vehicle) if triggered by the algorithm. Rescue dextrose was given for plasma glucose <55 mg/dL or neuroglycopenia. RESULTS: Twelve participants (11 females/1 male, age 52 ± 2, 8 ± 1 years postsurgery, mean ± SEM) completed all visits. Predictive hypoglycemia alerts prompted automated drug delivery postmeal, when sensor glucose was 114 ± 7 vs 121 ± 5 mg/dL (P = .39). Seven participants required rescue glucose after vehicle but not glucagon (P = .008). Five participants had severe hypoglycemia (<55 mg/dL) after vehicle but not glucagon (P = .03). Nadir plasma glucose was higher with glucagon vs vehicle (67 ± 3 vs 59 ± 2 mg/dL, P = .004). Plasma glucagon rose after glucagon delivery (1231 ± 187 vs 16 ± 1 pg/mL at 30 minutes, P = .001). No rebound hyperglycemia occurred. Transient infusion site discomfort was reported with both glucagon (n = 11/12) and vehicle (n = 10/12). No other adverse events were observed. CONCLUSION: A CGM-guided closed-loop rescue system can detect imminent hypoglycemia and deliver glucagon, reducing severe hypoglycemia in PBH. CLINICAL TRIALS REGISTRATION: NCT03255629.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Obesidad Mórbida / Fármacos Gastrointestinales / Glucagón / Cirugía Bariátrica / Hipoglucemia Tipo de estudio: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Aspecto: Patient_preference Límite: Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Endocrinol Metab Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Obesidad Mórbida / Fármacos Gastrointestinales / Glucagón / Cirugía Bariátrica / Hipoglucemia Tipo de estudio: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Aspecto: Patient_preference Límite: Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Endocrinol Metab Año: 2020 Tipo del documento: Article
...