Your browser doesn't support javascript.
loading
Ultrasound Imaging of the Superficial Fascial System Can Predict the Subcutaneous Strength of Abdominal Tissue Using Mean Gray Value Quantification.
Guidry, Richard F; McCarthy, Michelle E; Straughan, David M; St Hilaire, Hugo; Schuster, Jason D; Dancisak, Michael; Lindsey, John T.
Afiliación
  • Guidry RF; From the Division of Plastic and Reconstructive Surgery, Department of Surgery, Louisiana State University Health Sciences Center; the Division of Plastic and Reconstructive Surgery, Tulane University School of Medicine; and the Center for Anatomical and Movement Sciences, Tulane University.
  • McCarthy ME; From the Division of Plastic and Reconstructive Surgery, Department of Surgery, Louisiana State University Health Sciences Center; the Division of Plastic and Reconstructive Surgery, Tulane University School of Medicine; and the Center for Anatomical and Movement Sciences, Tulane University.
  • Straughan DM; From the Division of Plastic and Reconstructive Surgery, Department of Surgery, Louisiana State University Health Sciences Center; the Division of Plastic and Reconstructive Surgery, Tulane University School of Medicine; and the Center for Anatomical and Movement Sciences, Tulane University.
  • St Hilaire H; From the Division of Plastic and Reconstructive Surgery, Department of Surgery, Louisiana State University Health Sciences Center; the Division of Plastic and Reconstructive Surgery, Tulane University School of Medicine; and the Center for Anatomical and Movement Sciences, Tulane University.
  • Schuster JD; From the Division of Plastic and Reconstructive Surgery, Department of Surgery, Louisiana State University Health Sciences Center; the Division of Plastic and Reconstructive Surgery, Tulane University School of Medicine; and the Center for Anatomical and Movement Sciences, Tulane University.
  • Dancisak M; From the Division of Plastic and Reconstructive Surgery, Department of Surgery, Louisiana State University Health Sciences Center; the Division of Plastic and Reconstructive Surgery, Tulane University School of Medicine; and the Center for Anatomical and Movement Sciences, Tulane University.
  • Lindsey JT; From the Division of Plastic and Reconstructive Surgery, Department of Surgery, Louisiana State University Health Sciences Center; the Division of Plastic and Reconstructive Surgery, Tulane University School of Medicine; and the Center for Anatomical and Movement Sciences, Tulane University.
Plast Reconstr Surg ; 145(5): 1173-1181, 2020 05.
Article en En | MEDLINE | ID: mdl-32332535
ABSTRACT

BACKGROUND:

This study is the first to correlate sonographic findings of subcutaneous tissue to structural and biomechanical properties.

METHODS:

Precisely sized tissue specimens (59 samples) were collected from five abdominoplasty procedures. A Philips Lumify L12-4 linear array probe, connected to an Android tablet, was used to obtain ultrasound images of the superficial fascial system. A no. 1 Vicryl suture on a CTX needle placed though a needle guide within a three-dimensionally printed template ensured equal bites of subcutaneous tissue across specimens. Suture pull-out strength was measured until failure at a displacement rate of 2.12 mm/second using an Admet MTEST Quattro. Mean gray value for the superficial fascial system in associated ultrasonographic images was quantified by CellProfiler.

RESULTS:

Superficial fascial system visualization can be accomplished using high-resolution portable ultrasound. Comparing multiple specimens' imaging, interpatient and intrapatient variability of superficial fascial system quantity and structural characteristics are apparent. The superficial fascial system is highly abundant in some patients, but has limited presence in others. Individual-specimen mean gray value and whole-patient mean gray value positively correlated with tissue tensile strength (p = 0.006) and patient-average tissue tensile strength (p = 0.036), respectively. Whole-patient mean gray value accounted for 98.5 percent of the variance seen in patient-average tensile strength, making it a strong predictor for tensile strength.

CONCLUSIONS:

Portable ultrasound and image-processing technology can visualize, quantify, and predict subcutaneous tissue strength of the superficial fascial system. The superficial fascial system quantity correlates with suture tensile strength. Clinically, preoperative superficial fascial system quantification may aid in outcome predictions, manage patient expectations, and potentially lower complication rates. CLINICAL QUESTION/LEVEL OF EVIDENCE Diagnostic, V.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Pared Abdominal / Tejido Subcutáneo Tipo de estudio: Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Plast Reconstr Surg Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Pared Abdominal / Tejido Subcutáneo Tipo de estudio: Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Plast Reconstr Surg Año: 2020 Tipo del documento: Article
...