Your browser doesn't support javascript.
loading
Fast charge exchange recombination spectroscopy on HuanLiu-2A tokamak.
He, X X; Yu, D L; Yan, L W; Liu, L; Chen, W J; Wei, Y L; He, X F; Ma, Q; Shi, Z B; Liu, Yi; Yang, Q W; Xu, M; Duan, X R.
Afiliación
  • He XX; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • Yu DL; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • Yan LW; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • Liu L; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • Chen WJ; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • Wei YL; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • He XF; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • Ma Q; College of Physics and Optoelectronics Technology, Baoji University of Arts and Sciences, Baoji, Shanxi 721016, China.
  • Shi ZB; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • Liu Y; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • Yang QW; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • Xu M; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
  • Duan XR; Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041, China.
Rev Sci Instrum ; 91(5): 053504, 2020 May 01.
Article en En | MEDLINE | ID: mdl-32486744
A Fast Charge eXchange Recombination Spectroscopy (CXRS) diagnostic with eight radial channels has been implemented on a HuanLiu-2A (HL-2A) tokamak with a time resolution of up to 10 kHz monitoring helium II spectra or 1 kHz monitoring carbon VI spectra. The crucial aspects of the fast CXRS are to improve the spectral intensity and the acquisition frequency. The spectral intensity has been greatly enhanced by customized fiber bundles. The main boost in optimizing the acquisition frequency is achieved by binning more pixel rows of the charge coupled device (CCD) representing one radial channel and by reducing the effective image area of the CCD. Consequently, the sawtooth oscillations of ion temperature and rotation velocity are continuously observed for the first time in the HL-2A tokamak.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2020 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2020 Tipo del documento: Article País de afiliación: China
...