Your browser doesn't support javascript.
loading
Development of Self-Healing Cement Slurry through the Incorporation of Dual-Encapsulated Polyacrylamide for the Prevention of Water Ingress in Oil Well.
Richhariya, G; Dora, D T K; Parmar, K R; Pant, K K; Singhal, N; Lal, K; Kundu, P P.
Afiliación
  • Richhariya G; Department of Petroleum & Energy Studies, DIT University, Dehradun 248009, India.
  • Dora DTK; Department of Petroleum & Energy Studies, DIT University, Dehradun 248009, India.
  • Parmar KR; Department Chemical Engineering, Indian Institute of Technology, Delhi 110016, India.
  • Pant KK; Department Chemical Engineering, Indian Institute of Technology, Delhi 110016, India.
  • Singhal N; Department of Chemistry, DIT University, Dehradun, 248009, India.
  • Lal K; Institute of Drilling Technology, ONGC, Dehradun 248003, India.
  • Kundu PP; Department of Chemical Engineering, Indian Institute of Technology, Roorkee 247667, India.
Materials (Basel) ; 13(13)2020 Jun 29.
Article en En | MEDLINE | ID: mdl-32610621
ABSTRACT
In the present work, a novel cross-linked polymer was synthesized though the anionic polymerization of cyanoacrylate with moisture as an initiator, methylene-bis-acrylamide as a cross-linker, and linseed oil as a spacer. Two layers of the synthesized polymer was coated over polyacrylamide for its homogenous impregnation in Class-G cement slurry for the synthesis of cement core. Fourier Transformation Infrared spectroscopy and X-Ray diffraction spectrum of the synthesized polymer and cement core were obtained to investigate the presence of different functional groups and phases. Moreover, the morphologies of the dual-encapsulated polyacrylamide was observed through scanning electron microscopy. Furthermore, the water-absorption capacity of the synthesized dual-encapsulated polyacrylamide in normal and saline conditions were tested. A cement core impregnated with 16% of dosage of dual-encapsulated polyacrylamide possesses an effective self-healing capability during the water-flow test. Moreover, the maximum linear expansion of the cement core was observed to be 26%. Thus, the impregnation of dual-encapsulated polyacrylamide in cement slurry can exhibit a superior self-healing behavior upon water absorption in an oil well.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Materials (Basel) Año: 2020 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Materials (Basel) Año: 2020 Tipo del documento: Article País de afiliación: India
...