Your browser doesn't support javascript.
loading
Smartphone-Based Whole-Cell Biosensor Platform Utilizing an Immobilization Approach on a Filter Membrane Disk for the Monitoring of Water Toxicants.
Ma, Junning; Harpaz, Dorin; Liu, Yang; Eltzov, Evgeni.
Afiliación
  • Ma J; Department of Postharvest Science, Institute of Postharvest and Food Sciences, the Volcani Center, Agricultural Research Organization, Bet Dagan 50250, Israel.
  • Harpaz D; Key Laboratory of Agro-Products Quality and Safety Control in Storage and Transport Process, Ministry of Agriculture and Rural Affairs, Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, China.
  • Liu Y; Department of Postharvest Science, Institute of Postharvest and Food Sciences, the Volcani Center, Agricultural Research Organization, Bet Dagan 50250, Israel.
  • Eltzov E; Institute of Biochemistry, Food science and Nutrition, Faculty of Agriculture, Food and Environment, the Hebrew University of Jerusalem, Rehovot 76100, Israel.
Sensors (Basel) ; 20(19)2020 Sep 25.
Article en En | MEDLINE | ID: mdl-32992697
Bioluminescent bacteria whole-cell biosensors (WCBs) have been widely used in a range of sensing applications in environmental monitoring and medical diagnostics. However, most of them use planktonic bacteria cells that require complicated signal measurement processes and therefore limit the portability of the biosensor device. In this study, a simple and low-cost immobilization method was examined. The bioluminescent bioreporter bacteria was absorbed on a filter membrane disk. Further optimization of the immobilization process was conducted by comparing different surface materials (polyester and parafilm) or by adding glucose and ampicillin. The filter membrane disks with immobilized bacteria cells were stored at -20 °C for three weeks without a compromise in the stability of its biosensing functionality for water toxicants monitoring. Also, the bacterial immobilized disks were integrated with smartphones-based signal detection. Then, they were exposed to water samples with ethanol, chloroform, and H2O2, as common toxicants. The sensitivity of the smartphone-based WCB for the detection of ethanol, chloroform, and H2O2 was 1% (v/v), 0.02% (v/v), and 0.0006% (v/v), respectively. To conclude, this bacterial immobilization approach demonstrated higher sensitivity, portability, and improved storability than the planktonic counterpart. The developed smartphone-based WCB establishes a model for future applications in the detection of environmental water toxicants.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 2_ODS3 Problema de salud: 2_quimicos_contaminacion Asunto principal: Contaminantes del Agua / Técnicas Biosensibles / Monitoreo del Ambiente / Células Inmovilizadas / Teléfono Inteligente Idioma: En Revista: Sensors (Basel) Año: 2020 Tipo del documento: Article País de afiliación: Israel

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 2_ODS3 Problema de salud: 2_quimicos_contaminacion Asunto principal: Contaminantes del Agua / Técnicas Biosensibles / Monitoreo del Ambiente / Células Inmovilizadas / Teléfono Inteligente Idioma: En Revista: Sensors (Basel) Año: 2020 Tipo del documento: Article País de afiliación: Israel
...