Your browser doesn't support javascript.
loading
A ratiometric electrochemiluminescence resonance energy transfer platform based on novel dye BODIPY derivatives for sensitive detection of lactoferrin.
Lu, Yao; Ke, Hong; Wang, Yang; Zhang, Yao; Li, Huan; Huang, Chusen; Jia, Nengqin.
Afiliación
  • Lu Y; The Education Ministry Key Laboratory of Resource Chemistry, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai, 200234, PR China.
  • Ke H; The Education Ministry Key Laboratory of Resource Chemistry, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai, 200234, PR China.
  • Wang Y; The Education Ministry Key Laboratory of Resource Chemistry, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai, 200234, PR China.
  • Zhang Y; The Education Ministry Key Laboratory of Resource Chemistry, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai, 200234, PR China.
  • Li H; The Education Ministry Key Laboratory of Resource Chemistry, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai, 200234, PR China.
  • Huang C; The Education Ministry Key Laboratory of Resource Chemistry, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai, 200234, PR China.
  • Jia N; The Education Ministry Key Laboratory of Resource Chemistry, Shanghai Key Laboratory of Rare Earth Functional Materials, College of Chemistry and Materials Science, Shanghai Normal University, Shanghai, 200234, PR China. Electronic address: nqjia@shnu.edu.cn.
Biosens Bioelectron ; 170: 112664, 2020 Dec 15.
Article en En | MEDLINE | ID: mdl-33011620
A ratiometric electrochemiluminescence resonance energy transfer (ECL-RET) platform depended on novel dye BODIPY derivatives was proposed for rapid detection of lactoferrin. This ECL-RET platform is composed of aptamer decorated BODIPY composites and C60@BSA, in which BODIPY derivative is the ECL probe and can generate significant resonance energy transfer with K2S2O8. BODIPY derivative and K2S2O8 are used as built-in reference signal and calibration signal respectively to eliminate background signal and abnormal change signal by double signal self-calibration process. At the same time, C60, as the accelerator of K2S2O8, can effectively increase the ECL signal and further transfer as much energy as possible to BODIPY derivative. Under optimal conditions, the constructed ECL-RET platform exhibited sensitive detection of lactoferrin in the wide linear range of 10-4- 850 ng/mL with a LOD of 42 fg/mL. Meanwhile, the proposed ECL-RET aptasensor demonstrated superior stability, specificity and reproducibility, displaying favorable application value in practical diagnosis of this method.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Técnicas Electroquímicas Tipo de estudio: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Técnicas Electroquímicas Tipo de estudio: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2020 Tipo del documento: Article
...