Sources of Variability in Vena Contracta Area Measurement for Tricuspid Regurgitation Severity Grading: Comparison of Technical Settings and Vendors.
Liu, Yu; Chen, Beiqi; Zhang, Yue; Zuo, Wuxu; Li, Quan; Jin, Ling; Kong, Dehong; Pan, Cuizhen; Dong, Lili; Shu, Xianhong; Ge, Junbo.
Afiliación
  • Liu Y; Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai, China; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China; Shanghai Institute of Cardiovascular Diseases, Shanghai, China.
  • Chen B; Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai, China; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China; Shanghai Institute of Cardiovascular Diseases, Shanghai, China.
  • Zhang Y; Department of Biostatistics, School of Public Health, Fudan University, Shanghai, China.
  • Zuo W; Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai, China; Shanghai Institute of Cardiovascular Diseases, Shanghai, China.
  • Li Q; Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai, China; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China; Shanghai Institute of Cardiovascular Diseases, Shanghai, China.
  • Jin L; Shanghai Medical College, Fudan University, Shanghai, China.
  • Kong D; Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai, China; Shanghai Institute of Cardiovascular Diseases, Shanghai, China.
  • Pan C; Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai, China; Shanghai Institute of Cardiovascular Diseases, Shanghai, China.
  • Dong L; Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai, China; Shanghai Institute of Cardiovascular Diseases, Shanghai, China. Electronic address: dong.lili@zs-hospital.sh.cn.
  • Shu X; Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai, China; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China; Shanghai Institute of Cardiovascular Diseases, Shanghai, China.
  • Ge J; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China; Shanghai Institute of Cardiovascular Diseases, Shanghai, China.
J Am Soc Echocardiogr ; 34(3): 270-278.e1, 2021 03.
Article en En | MEDLINE | ID: mdl-33166630
BACKGROUND: Previous studies found different cutoffs of vena contracta area (VCA) to define severe tricuspid regurgitation (TR). The aim of this study was to investigate the factors associated with such variability by comparing technical variables and vendors. METHODS: Sixty-nine patients with scheduled tricuspid surgery were included in this prospective study. For each patient, TR data sets were obtained on three-dimensional color Doppler transthoracic echocardiography on at least two of three systems: GE Vivid E95 (n = 39), Siemens SC2000 Prime (n = 64), and Philips EPIQ 7C (n = 60). VCA was measured using default settings or with color baseline shifted on all three platforms and with minimal color gain (10%-20%) on the GE platform. RESULTS: Color gain reduction and baseline shift caused significant change sin VCA measurement (-46% and 10%, respectively). Intervendor comparison exhibited wide limits of agreement (narrowest range, -74% to 167%), with either default or optimized settings. Different technical settings, platforms, and reference methods all produced different VCA cutoffs for severe TR. CONCLUSIONS: VCA measurement in TR is sensitive to technical factors and demonstrates intervendor variability. Technical variables in VCA measurement should be reported in detail to allow comparison among research studies. The same vendor and settings should be used for longitudinal analysis of TR VCA in the same patient in multivendor echocardiography laboratories.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Insuficiencia de la Válvula Tricúspide / Ecocardiografía Tridimensional Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: J Am Soc Echocardiogr Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Insuficiencia de la Válvula Tricúspide / Ecocardiografía Tridimensional Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: J Am Soc Echocardiogr Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2021 Tipo del documento: Article País de afiliación: China
...