Your browser doesn't support javascript.
loading
Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty in Patients with Previous Acetabular Fractures: A Minimum 5-Year Follow-Up Study.
Min, Byung-Woo; Bae, Ki-Cheor; Cho, Chul-Hyun; Son, Eun-Suck; Lee, Kyung-Jae; Lee, Si-Wook.
Afiliación
  • Min BW; Department of Orthopaedic Surgery, School of Medicine, Keimyung University, Daegu, Korea.
  • Bae KC; Department of Orthopaedic Surgery, Dongsan Hospital, Keimyung University, 1035 Dalgubeol-daero, Dalseo-gu, Daegu, 42601 Korea.
  • Cho CH; Department of Orthopaedic Surgery, School of Medicine, Keimyung University, Daegu, Korea.
  • Son ES; Department of Orthopaedic Surgery, Dongsan Hospital, Keimyung University, 1035 Dalgubeol-daero, Dalseo-gu, Daegu, 42601 Korea.
  • Lee KJ; Department of Orthopaedic Surgery, School of Medicine, Keimyung University, Daegu, Korea.
  • Lee SW; Department of Orthopaedic Surgery, Dongsan Hospital, Keimyung University, 1035 Dalgubeol-daero, Dalseo-gu, Daegu, 42601 Korea.
Indian J Orthop ; 54(Suppl 2): 239-245, 2020 Dec.
Article en En | MEDLINE | ID: mdl-33194097
ABSTRACT

BACKGROUND:

Outcomes of THA after acetabular fracture are generally less favorable than those of the nontraumatic arthritis due to a higher rate of cup loosening and osteolysis. We, therefore, investigated whether highly cross-linked polyethylene liners positively impact outcomes of THA in patients with posttraumatic osteoarthritis after acetabular fracture.

METHODS:

We retrospectively evaluated 39 patients with previous acetabular fracture who underwent THA using highly cross-linked polyethylene liner after a mean 8.5 year follow-up. All procedures were performed at a single institution by a single surgeon using the same type of THA implants. Wear measurements were performed using a computer-assisted PolyWare software. Osteolysis was evaluated with use of radiography and computed tomography.

RESULTS:

The mean preoperative Harris hip score was 44.4 points, which improved to 93.1 points at final follow-up. Neither femoral nor acetabular components displayed mechanical loosening and no components had been revised. Radiographs and CT scans did not demonstrate osteolysis. The mean linear wear was 0.043 mm/y (range 0-0.098 mm/y). With the data available, univariate regression analysis suggests that age, gender, weight, initial fracture type, the duration of follow-up, activity level, liner thickness, acetabular cup inclination, and the necessity of bone graft had no influence on liner penetration.

CONCLUSION:

While the long-term effects of the polyethylene particles from highly cross-linked polyethylene remain unknown, implant survivorship and wear data in this study are promising for this high-risk population. Our encouraging results support the continued use of this type of polyethylene in patients after acetabular fractures. LEVEL OF EVIDENCE Level IV Therapeutic study.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Observational_studies / Prognostic_studies Idioma: En Revista: Indian J Orthop Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Observational_studies / Prognostic_studies Idioma: En Revista: Indian J Orthop Año: 2020 Tipo del documento: Article
...