Your browser doesn't support javascript.
loading
Fluid-Structure Interaction Simulation of an Intra-Atrial Fontan Connection.
Tang, Elaine; Wei, Zhenglun Alan; Fogel, Mark A; Veneziani, Alessandro; Yoganathan, Ajit P.
Afiliación
  • Tang E; School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Wei ZA; Department of Biomedical Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA.
  • Fogel MA; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Atlanta, GA 30332, USA.
  • Veneziani A; Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA 19104, USA.
  • Yoganathan AP; Department of Mathematics and Computer Science, Emory University, Atlanta, GA 30322, USA.
Biology (Basel) ; 9(12)2020 Nov 24.
Article en En | MEDLINE | ID: mdl-33255292
Total cavopulmonary connection (TCPC) hemodynamics has been hypothesized to be associated with long-term complications in single ventricle heart defect patients. Rigid wall assumption has been commonly used when evaluating TCPC hemodynamics using computational fluid dynamics (CFD) simulation. Previous study has evaluated impact of wall compliance on extra-cardiac TCPC hemodynamics using fluid-structure interaction (FSI) simulation. However, the impact of ignoring wall compliance on the presumably more compliant intra-atrial TCPC hemodynamics is not fully understood. To narrow this knowledge gap, this study aims to investigate impact of wall compliance on an intra-atrial TCPC hemodynamics. A patient-specific model of an intra-atrial TCPC is simulated with an FSI model. Patient-specific 3D TCPC anatomies were reconstructed from transverse cardiovascular magnetic resonance images. Patient-specific vessel flow rate from phase-contrast magnetic resonance imaging (MRI) at the Fontan pathway and the superior vena cava under resting condition were prescribed at the inlets. From the FSI simulation, the degree of wall deformation was compared with in vivo wall deformation from phase-contrast MRI data as validation of the FSI model. Then, TCPC flow structure, power loss and hepatic flow distribution (HFD) were compared between rigid wall and FSI simulation. There were differences in instantaneous pressure drop, power loss and HFD between rigid wall and FSI simulations, but no difference in the time-averaged quantities. The findings of this study support the use of a rigid wall assumption on evaluation of time-averaged intra-atrial TCPC hemodynamic metric under resting breath-held condition.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: Biology (Basel) Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: Biology (Basel) Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos
...