Your browser doesn't support javascript.
loading
Characterizing the Air Emissions, Transport, and Deposition of Per- and Polyfluoroalkyl Substances from a Fluoropolymer Manufacturing Facility.
D'Ambro, Emma L; Pye, Havala O T; Bash, Jesse O; Bowyer, James; Allen, Chris; Efstathiou, Christos; Gilliam, Robert C; Reynolds, Lara; Talgo, Kevin; Murphy, Benjamin N.
Afiliación
  • D'Ambro EL; Oak Ridge Institute for Science Education, Oak Ridge, Tennessee 37831, United States.
  • Pye HOT; Center for Environmental Measurement and Modeling, U.S. EPA, Research Triangle Park, North Carolina 27711, United States.
  • Bash JO; Center for Environmental Measurement and Modeling, U.S. EPA, Research Triangle Park, North Carolina 27711, United States.
  • Bowyer J; Center for Environmental Measurement and Modeling, U.S. EPA, Research Triangle Park, North Carolina 27711, United States.
  • Allen C; North Carolina Division of Air Quality, NC DEQ, Raleigh, North Carolina 27603, United States.
  • Efstathiou C; General Dynamics Information Technology, Research Triangle Park, North Carolina 28311, United States.
  • Gilliam RC; General Dynamics Information Technology, Research Triangle Park, North Carolina 28311, United States.
  • Reynolds L; Center for Environmental Measurement and Modeling, U.S. EPA, Research Triangle Park, North Carolina 27711, United States.
  • Talgo K; General Dynamics Information Technology, Research Triangle Park, North Carolina 28311, United States.
  • Murphy BN; General Dynamics Information Technology, Research Triangle Park, North Carolina 28311, United States.
Environ Sci Technol ; 55(2): 862-870, 2021 01 19.
Article en En | MEDLINE | ID: mdl-33395278
Per- and polyfluoroalkyl substances (PFASs) have been released into the environment for decades, yet contributions of air emissions to total human exposure, from inhalation and drinking water contamination via deposition, are poorly constrained. The atmospheric transport and fate of a PFAS mixture from a fluoropolymer manufacturing facility in North Carolina were investigated with the Community Multiscale Air Quality (CMAQ) model applied at high resolution (1 km) and extending ∼150 km from the facility. Twenty-six explicit PFAS compounds, including GenX, were added to CMAQ using current best estimates of air emissions and relevant physicochemical properties. The new model, CMAQ-PFAS, predicts that 5% by mass of total emitted PFAS and 2.5% of total GenX are deposited within ∼150 km of the facility, with the remainder transported out. Modeled air concentrations of total GenX and total PFAS around the facility can reach 24.6 and 8500 ng m-3 but decrease to ∼0.1 and ∼10 ng m-3 at 35 km downwind, respectively. We find that compounds with acid functionality have higher deposition due to enhanced water solubility and pH-driven partitioning to aqueous media. To our knowledge, this is the first modeling study of the fate of a comprehensive, chemically resolved suite of PFAS air emissions from a major manufacturing source.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 2_ODS3 Problema de salud: 2_quimicos_contaminacion Asunto principal: Contaminantes Químicos del Agua / Purificación del Agua / Fluorocarburos Tipo de estudio: Prognostic_studies Límite: Humans País/Región como asunto: America do norte Idioma: En Revista: Environ Sci Technol Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 2_ODS3 Problema de salud: 2_quimicos_contaminacion Asunto principal: Contaminantes Químicos del Agua / Purificación del Agua / Fluorocarburos Tipo de estudio: Prognostic_studies Límite: Humans País/Región como asunto: America do norte Idioma: En Revista: Environ Sci Technol Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos
...