Your browser doesn't support javascript.
loading
Optimization of adiabatic pulses for pulsed arterial spin labeling at 7 tesla: Comparison with pseudo-continuous arterial spin labeling.
Wang, Kai; Shao, Xingfeng; Yan, Lirong; Ma, Samantha J; Jin, Jin; Wang, Danny J J.
Afiliación
  • Wang K; Laboratory of FMRI Technology (LOFT), USC Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
  • Shao X; Laboratory of FMRI Technology (LOFT), USC Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
  • Yan L; Laboratory of FMRI Technology (LOFT), USC Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
  • Ma SJ; Department of Neurology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
  • Jin J; Laboratory of FMRI Technology (LOFT), USC Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
  • Wang DJJ; Siemens Medical Solutions USA, Inc., Los Angeles, California, USA.
Magn Reson Med ; 85(6): 3227-3240, 2021 06.
Article en En | MEDLINE | ID: mdl-33427349
ABSTRACT

PURPOSE:

To optimize and evaluate adiabatic pulses for pulsed arterial spin labeling at ultrahigh field 7 tesla.

METHODS:

Four common adiabatic inversion pulses, including hyperbolic secant, wideband uniform rate smooth truncation, frequency offset corrected inversion, and time-resampled frequency offset corrected inversion pulses, were optimized based on a custom-defined loss function that included labeling efficiency and inversion band uniformity. The optimized pulses were implemented in flow-sensitive alternating inversion recovery sequences and tested on phantom and 11 healthy volunteers with 2 constraints 1) specific absorption rate normalized; and 2) equal peak RF amplitude, respectively. A pseudo-continuous arterial spin labeling sequence was implemented for comparison. Quantitative metrics such as perfusion and relative labeling efficiency versus residual tissue signal were calculated.

RESULTS:

Among the 4 pulses, the wideband uniform rate smooth truncation pulse yielded the lowest loss in simulation and achieved a good balance between labeling efficiency and residual tissue signal from both phantom and in vivo experiments. Wideband uniform rate smooth truncation-pulsed arterial spin labeling showed significantly higher relative labeling efficiency compared to the other sequences (P < .01), whereas the perfusion signal was increased by 40% when the highest B1+ amplitude was used. The 4 pulsed arterial spin labeling sequences yielded comparable perfusion signals compared to pseudo-continuous arterial spin labeling but with less than half the specific absorption rate.

CONCLUSION:

Optimized wideband uniform rate smooth truncation pulse with the highest B1+ amplitude allowed was recommended for 7 tesla pulsed arterial spin labeling.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arterias / Imagen por Resonancia Magnética Límite: Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arterias / Imagen por Resonancia Magnética Límite: Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos
...