Quantification of regurgitation in mitral valve prolapse with automated real time echocardiographic 3D proximal isovelocity surface area: multimodality consistency and role of eccentricity index.
Spampinato, Ricardo A; Lindemann, Frank; Jahnke, Cosima; Paetsch, Ingo; Fahr, Florian; Sieg, Franz; von Roeder, Maximilian; Noack, Thilo; Hilbert, Sebastian; Löbe, Susanne; Strotdrees, Elfriede; Hindricks, Gerhard; Borger, Michael A.
Afiliación
  • Spampinato RA; University Department for Cardiac Surgery, HELIOS Heart Center Leipzig, Strümpellstraße 39, 04289, Leipzig, Germany. spampinatoricardo@gmail.com.
  • Lindemann F; Department of Electrophysiology, HELIOS Leipzig Heart Center, Leipzig, Germany.
  • Jahnke C; Department of Electrophysiology, HELIOS Leipzig Heart Center, Leipzig, Germany.
  • Paetsch I; Department of Electrophysiology, HELIOS Leipzig Heart Center, Leipzig, Germany.
  • Fahr F; University Department for Cardiac Surgery, HELIOS Heart Center Leipzig, Strümpellstraße 39, 04289, Leipzig, Germany.
  • Sieg F; University Department for Cardiac Surgery, HELIOS Heart Center Leipzig, Strümpellstraße 39, 04289, Leipzig, Germany.
  • von Roeder M; Department of Cardiology, HELIOS Leipzig Heart Center, Leipzig, Germany.
  • Noack T; University Department for Cardiac Surgery, HELIOS Heart Center Leipzig, Strümpellstraße 39, 04289, Leipzig, Germany.
  • Hilbert S; Department of Electrophysiology, HELIOS Leipzig Heart Center, Leipzig, Germany.
  • Löbe S; Department of Electrophysiology, HELIOS Leipzig Heart Center, Leipzig, Germany.
  • Strotdrees E; University Department for Cardiac Surgery, HELIOS Heart Center Leipzig, Strümpellstraße 39, 04289, Leipzig, Germany.
  • Hindricks G; Department of Electrophysiology, HELIOS Leipzig Heart Center, Leipzig, Germany.
  • Borger MA; University Department for Cardiac Surgery, HELIOS Heart Center Leipzig, Strümpellstraße 39, 04289, Leipzig, Germany.
Int J Cardiovasc Imaging ; 37(6): 1947-1959, 2021 Jun.
Article en En | MEDLINE | ID: mdl-33616785
ABSTRACT
Three-dimensional transthoracic echocardiography (3D-TTE) provides a semi-automated proximal isovelocity surface area method (3D-PISA) to obtain quantitative parameters. Data assessing regurgitation severity in mitral valve prolapse (MVP) are scarce, so we assessed the 3D-PISA method compared with 2D-PISA and cardiovascular magnetic resonance (CMR) and the role of an eccentricity index. We evaluated the 3D-PISA method for assessing MR in 54 patients with MVP (57 ± 14 years; 42 men; 12 mild/mild-moderate; 12 moderate-severe; and 30 severe MR). Role of an asymmetric (i.e. eccentricity index ≥ 1.25) flow convergence region (FCR) and inter-modality consistency were then assessed. 3D-PISA derived regurgitant volume (RVol) showed a good correlation with 2D-PISA and CMR derived parameters (r = 0.86 and r = 0.81, respectively). The small mean differences with 2D-PISA derived RVol did not reach statistical significance in overall population (5.7 ± 23 ml, 95% CI - 0.6 to 12; p = 0.08) but differed in those with asymmetric 3D-FCR (n = 21; 2D-PISA 72 ± 36 ml vs. 3D-PISA 93 ± 47 ml; p = 0.001). RVol mean values were higher using PISA methods (CMR 57 ± 33 ml; 2D-PISA 73 ± 39 ml; and 3D-PISA 79 ± 45 ml) and an overestimation was observed when CMR was used as reference (2D-PISA vs. CMR mean difference 15.8 ml [95% CI 10-22, p < 0.001]; and 3D-PISA vs. CMR 21.5 ml [95% CI 14-29, p < 0.001]). Intra- and inter-observer reliability was excellent (ICC 0.91-0.99), but with numerically lower coefficient of variation for 3D-PISA (8%-10% vs. 2D-PISA 12%-16%). 3D-PISA method for assessing regurgitation in MVP may enable analogous evaluation compared to standard 2D-PISA, but with overestimation in case of asymmetric FCR or when CMR is used as reference method.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prolapso de la Válvula Mitral / Ecocardiografía Tridimensional / Insuficiencia de la Válvula Mitral Tipo de estudio: Etiology_studies / Prognostic_studies Límite: Humans / Male Idioma: En Revista: Int J Cardiovasc Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prolapso de la Válvula Mitral / Ecocardiografía Tridimensional / Insuficiencia de la Válvula Mitral Tipo de estudio: Etiology_studies / Prognostic_studies Límite: Humans / Male Idioma: En Revista: Int J Cardiovasc Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2021 Tipo del documento: Article País de afiliación: Alemania
...