Your browser doesn't support javascript.
loading
Application of low-dose CT to the creation of 3D-printed kidney and perinephric tissue models for laparoscopic nephrectomy.
Li, Guan; Dong, Jie; Cao, Zhiqiang; Wang, Jinbao; Cao, Dongbing; Zhang, Xin; Zhang, Longjiang; Lu, Guangming.
Afiliación
  • Li G; Department of Radiology, Jinling Hospital, Medical School of Nanjing University, Nanjing, China.
  • Dong J; Department of Urology, Jinling Hospital, Medical School of Nanjing University, Nanjing, China.
  • Cao Z; Department of Urology, General Hospital of Northern Theater Command, Shenyang, China.
  • Wang J; Department of Radiology, General Hospital of Northern Theater Command, Shenyang, China.
  • Cao D; Department of Urology, Cancer Hospital of China Medical University, Shenyang, China.
  • Zhang X; Department of Radiology, The First Affiliated Hospital of China Medical University, Shenyang, China.
  • Zhang L; Department of Radiology, Jinling Hospital, Medical School of Nanjing University, Nanjing, China.
  • Lu G; Department of Radiology, Jinling Hospital, Medical School of Nanjing University, Nanjing, China.
Cancer Med ; 10(9): 3077-3084, 2021 05.
Article en En | MEDLINE | ID: mdl-33797861
ABSTRACT

PURPOSE:

The aim of this study was to explore the feasibility of 3D printing of kidney and perinephric fat based on low-dose CT technology. PATIENTS AND

METHODS:

A total of 184 patients with stage T1 complex renal tumors who underwent laparoscopic nephrectomy were prospectively enrolled and divided into three groups group A (conventional dose kidney and perinephric fat 3D printing group, n = 62), group B (low-dose kidney and perinephric fat 3D printing, n = 64), and group C (conventional dose merely kidney 3D printing group, n = 58). The effective dose (ED), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were determined. The 3D printing quality was evaluated using a 4-point scale, and interobserver agreement was assessed using the intraclass correlation coefficient (ICC).

RESULTS:

The ED of group B was lower than that of group A, with a decrease of 55.1%. The subjective scores of 3D printing quality in all groups were 3 or 4 points. The interobserver agreement among the three observers in 3D printing quality was good (ICC = 0.84-0.92). The perioperative indexes showed that operation time (OT), warm ischemia time (WIT), estimated blood loss (EBL), and laparoscopic partial nephrectomy (LPN) conversion to laparoscopic radical nephrectomy (LRN) in groups A or B were significantly less than those in group C. LPN was more frequent in group A and group B than in group C (all p < 0.017). There were no significant differences in perioperative indexes between group A and group B (all p > 0.017).

CONCLUSION:

Low-dose CT technology can be effectively applied to 3D printing of kidney and perinephric fat and reduce the patient's radiation dose without compromising 3D printing quality. 3D printing of kidney and perinephric fat can significantly increase the success rate of LPN and decrease OT, WIT, and EBL.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Tejido Adiposo / Impresión Tridimensional / Riñón / Nefrectomía Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Cancer Med Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Tejido Adiposo / Impresión Tridimensional / Riñón / Nefrectomía Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Cancer Med Año: 2021 Tipo del documento: Article País de afiliación: China
...