Your browser doesn't support javascript.
loading
Noninvasive Assessment of Neuromechanical Coupling and Mechanical Efficiency of Parasternal Intercostal Muscle during Inspiratory Threshold Loading.
Lozano-García, Manuel; Estrada-Petrocelli, Luis; Torres, Abel; Rafferty, Gerrard F; Moxham, John; Jolley, Caroline J; Jané, Raimon.
Afiliación
  • Lozano-García M; Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), UPC Campus Diagonal-Besòs, Av. d'Eduard Maristany 10-14, 08019 Barcelona, Spain.
  • Estrada-Petrocelli L; Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain.
  • Torres A; Department of Automatic Control (ESAII), Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, 08028 Barcelona, Spain.
  • Rafferty GF; Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), UPC Campus Diagonal-Besòs, Av. d'Eduard Maristany 10-14, 08019 Barcelona, Spain.
  • Moxham J; Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 08028 Barcelona, Spain.
  • Jolley CJ; Facultad de Ingeniería, Universidad Latina de Panamá, Panama City 0823-00923, Panama.
  • Jané R; Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), UPC Campus Diagonal-Besòs, Av. d'Eduard Maristany 10-14, 08019 Barcelona, Spain.
Sensors (Basel) ; 21(5)2021 Mar 04.
Article en En | MEDLINE | ID: mdl-33806463
ABSTRACT
This study aims to investigate noninvasive indices of neuromechanical coupling (NMC) and mechanical efficiency (MEff) of parasternal intercostal muscles. Gold standard assessment of diaphragm NMC requires using invasive techniques, limiting the utility of this procedure. Noninvasive NMC indices of parasternal intercostal muscles can be calculated using surface mechanomyography (sMMGpara) and electromyography (sEMGpara). However, the use of sMMGpara as an inspiratory muscle mechanical output measure, and the relationships between sMMGpara, sEMGpara, and simultaneous invasive and noninvasive pressure measurements have not previously been evaluated. sEMGpara, sMMGpara, and both invasive and noninvasive measurements of pressures were recorded in twelve healthy subjects during an inspiratory loading protocol. The ratios of sMMGpara to sEMGpara, which provided muscle-specific noninvasive NMC indices of parasternal intercostal muscles, showed nonsignificant changes with increasing load, since the relationships between sMMGpara and sEMGpara were linear (R2 = 0.85 (0.75-0.9)). The ratios of mouth pressure (Pmo) to sEMGpara and sMMGpara were also proposed as noninvasive indices of parasternal intercostal muscle NMC and MEff, respectively. These indices, similar to the analogous indices calculated using invasive transdiaphragmatic and esophageal pressures, showed nonsignificant changes during threshold loading, since the relationships between Pmo and both sEMGpara (R2 = 0.84 (0.77-0.93)) and sMMGpara (R2 = 0.89 (0.85-0.91)) were linear. The proposed noninvasive NMC and MEff indices of parasternal intercostal muscles may be of potential clinical value, particularly for the regular assessment of patients with disordered respiratory mechanics using noninvasive wearable and wireless devices.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Diafragma / Músculos Intercostales Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2021 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Diafragma / Músculos Intercostales Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2021 Tipo del documento: Article País de afiliación: España
...