Your browser doesn't support javascript.
loading
Monte Carlo study of TG-43 dosimetry parameters of GammaMed Plus high dose rate 192 Ir brachytherapy source using TOPAS.
Wu, Jianan; Xie, Yaoqin; Ding, Zhen; Li, Feipeng; Wang, Luhua.
Afiliación
  • Wu J; Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China.
  • Xie Y; Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, China.
  • Ding Z; Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China.
  • Li F; Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, China.
  • Wang L; Shenzhen Key Laboratory of Advanced Machine Learning and Application, College of Mathematics and Statistics, Shenzhen University, Shenzhen, 518060, China.
J Appl Clin Med Phys ; 22(6): 146-153, 2021 Jun.
Article en En | MEDLINE | ID: mdl-33955134
ABSTRACT

PURPOSE:

To develop a simulation model for GammaMed Plus high dose rate 192 Ir brachytherapy source in TOPAS Monte Carlo software and validate it by calculating the TG-43 dosimetry parameters and comparing them with published data.

METHODS:

We built a model for GammaMed Plus high dose rate brachytherapy source in TOPAS. The TG-43 dosimetry parameters including air-kerma strength SK , dose-rate constant Λ, radial dose function gL (r), and 2D anisotropy function F(r,θ) were calculated using Monte Carlo simulation with Geant4 physics models and NNDC 192 Ir spectrum. Calculations using an old 192 Ir spectrum were also carried out to evaluate the impact of incident spectrum and cross sections. The results were compared with published data.

RESULTS:

For calculations using the NNDC spectrum, the air-kerma strength per unit source activity SK /A and Λ were 1.0139 × 10-7 U/Bq and 1.1101 cGy.h-1 .U-1 , which were 3.56% higher and 0.62% lower than the reference values, respectively. The gL (r) agreed with reference values within 1% for radial distances from 2 mm to 20 cm. For radial distances of 1, 3, 5, and 10 cm, the agreements between F(r,θ) from this work and the reference data were within 1.5% for 15° < Î¸ < 165°, and within 4% for all θ values. The discrepancies were attributed to the updated source spectrum and cross sections. They caused deviations of the SK /A of 2.90% and 0.64%, respectively. As for gL (r), they caused average deviations of -0.22% and 0.48%, respectively. Their impact on F(r,θ) was not quantified for the relatively high statistical uncertainties, but basically they did not result in significant discrepancies.

CONCLUSION:

A model for GammaMed Plus high dose rate 192 Ir brachytherapy source was developed in TOPAS and validated following TG-43 protocols, which can be used for future studies. The impact of updated incident spectrum and cross sections on the dosimetry parameters was quantified.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_financiamento_saude Asunto principal: Braquiterapia Tipo de estudio: Health_economic_evaluation Límite: Humans Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_financiamento_saude Asunto principal: Braquiterapia Tipo de estudio: Health_economic_evaluation Límite: Humans Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2021 Tipo del documento: Article País de afiliación: China
...