Your browser doesn't support javascript.
loading
Hueter Anterior Approach for Metal-on-Metal Hip Resurfacing Arthroplasty: 555 Cases at a Minimum Five-Year Follow-Up.
Suraci, Alison B; Bhullar, Ramandeep S; Dobransky, Johanna S; Beaulé, Paul E.
Afiliación
  • Suraci AB; Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON.
  • Bhullar RS; Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON.
  • Dobransky JS; Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON.
  • Beaulé PE; Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON; Scientist, The Ottawa Hospital Research Institute, Ottawa, ON.
J Arthroplasty ; 36(9): 3200-3208, 2021 Sep.
Article en En | MEDLINE | ID: mdl-33992480
BACKGROUND: Purpose of this study was to determine implant survivorship and resultant outcomes, including modes of failure, for metal-on-metal hip resurfacing through the Hueter anterior approach (HAA). METHODS: Retrospective review of cases from 2006 to 2015, resulted in 555 metal-on-metal hip resurfacing via HAA, mean age 49.4 ± 6.9 years and mean BMI 28.1 ± 5.3. Kaplan-Meier curves were used to assess implant survivorship. Evaluation of technique was based on radiographic assessment of component position at 6 weeks. Patient-reported outcome measures were assessed using 12-Item Short Form Survey 12, University of California Los Angeles activity, Western Ontario and McMaster Universities Osteoarthritis Index, and hip disability osteoarthritis outcome scores. RESULTS: At a mean follow-up of 9.18 years, survivorship was 95.0% at 5 years (95% CI: 93.2-96.8 years) and 92.5% at 10 years (95% CI: 90.0-95.0 years); men at 96.1% (95% CI: 94.3-97.9) and 93.8% (95% CI: 91.1-96.5), and women at 88.8% (95% CI: 81.9-95.7) and 85.6% (95% CI: 77.6-93.6), 5 and 10 years, respectively (P = .033). There were 37 revisions to total hips (7%) at a mean time of 3.3 years (SD 2.7). Indications for revision were aseptic loosening of acetabular (n = 12) and femoral component (n = 7) and pseudotumor (n = 6). Radiographic parameters were respectable and consistent, median acetabular inclination angle 41.2° and femoral stem shaft angle 137.7°. Patient-reported outcome measure scores significantly improved and remained stable at 2 and 5 years postoperatively. CONCLUSION: Although choice of surgical approach should always be based on surgeon's technical expertise, this study has shown that HAA is safe and effective for hip resurfacing. Mindful attention to long-term metal ion exposure must still be considered.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis Articulares de Metal sobre Metal / Prótesis de Cadera Tipo de estudio: Observational_studies / Prognostic_studies Aspecto: Patient_preference Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis Articulares de Metal sobre Metal / Prótesis de Cadera Tipo de estudio: Observational_studies / Prognostic_studies Aspecto: Patient_preference Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Asunto de la revista: ORTOPEDIA Año: 2021 Tipo del documento: Article
...