Your browser doesn't support javascript.
loading
A comparative life cycle assessment of stretchable and rigid electronics: a case study of cardiac monitoring devices.
Kokare, S; Asif, F M A; Mårtensson, G; Shoaib-Ul-Hasan, S; Rashid, A; Roci, M; Salehi, N.
Afiliación
  • Kokare S; Department of Production Engineering, KTH Royal Institute of Technology, Brinellvägen 68, 100 44 Stockholm, Sweden.
  • Asif FMA; Department of Production Engineering, KTH Royal Institute of Technology, Brinellvägen 68, 100 44 Stockholm, Sweden.
  • Mårtensson G; Department of Protein Science, KTH Royal Institute of Technology, Mycronic AB Nytorpsvägen 9, 183 03 Täby, Sweden.
  • Shoaib-Ul-Hasan S; Department of Production Engineering, KTH Royal Institute of Technology, Brinellvägen 68, 100 44 Stockholm, Sweden.
  • Rashid A; Department of Production Engineering, KTH Royal Institute of Technology, Brinellvägen 68, 100 44 Stockholm, Sweden.
  • Roci M; Department of Production Engineering, KTH Royal Institute of Technology, Brinellvägen 68, 100 44 Stockholm, Sweden.
  • Salehi N; Department of Production Engineering, KTH Royal Institute of Technology, Brinellvägen 68, 100 44 Stockholm, Sweden.
Int J Environ Sci Technol (Tehran) ; 19(4): 3087-3102, 2022.
Article en En | MEDLINE | ID: mdl-34054976
ABSTRACT
Stretchable electronics is a new innovation and becoming popular in various fields, especially in the healthcare sector. Since stretchable electronics use less printed circuit boards (PCBs), it is expected that the environmental performance of a stretchable electronics-based device is better than a rigid electronics-based device that provides the same functionalities. Yet, such a study is rarely available. Thus, the main purpose of this research is to perform a comparative life cycle analysis of stretchable and rigid electronics-based devices. This research combines both the case study approach and the research review approach. For the case study, a cardiac monitoring device with both stretchable and rigid electronics is used. The ISO 140442006 standard's prescribed LCA approach and ReCiPe 2016 Midpoint (Hierarchist) are followed for the impact assessment using the SimaPro 9.1 software. The LCA results show that the stretchable cardiac monitoring device has better environmental performance in all eighteen impact categories. This research also shows that the manufacturing process of stretchable electronics has lower environmental impacts than those for rigid electronics. The main reasons for the improved environmental performance of stretchable electronics are lower consumption of raw material as well as decreased energy consumption during manufacturing. Based on the LCA results of a cardiac monitoring device, the study concludes that stretchable electronics and their manufacturing process have better environmental performance in comparison with the rigid electronics and their manufacturing process.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Int J Environ Sci Technol (Tehran) Año: 2022 Tipo del documento: Article País de afiliación: Suecia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Int J Environ Sci Technol (Tehran) Año: 2022 Tipo del documento: Article País de afiliación: Suecia
...