[Ion chromatography for the determination of ethylamine in the workplace air].
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi
; 39(5): 363-365, 2021 May 20.
Article
en Zh
| MEDLINE
| ID: mdl-34074082
Objective: To establish a method for the determination of ethylamine in the air of the workplace by ion chromatography. Methods: In August 2020, ethylamine in the air of the workplace was adsorbed by a basic silica gel tube, and ultrasonically desorbed with a 1 mmol/L sulfuric acid solution, and then qualitatively and quantitatively determined by ion chromatography. Results: The linear range of the method was 0.014-50 µg/ml, and the linear equation of the standard curve was y=0.1243x+0.0429, the correlation coefficient was r=0.9997. The detection limit of the method was 4.29 µg/L, and the lower limit of quantification was 14.29 µg/L. The lowest quantitative concentration was 0.012 mg/m(3) (in term of sampling 6.0 L) . The average desorption efficiency of the method was 97.31%, the precision was 1.00%-1.68%, and the standard recovery rate was 96.33%-99.61%. Conclusion: This method is fast, sensitive and accurate, and can be used for the determination of ethylamine in the air of workplace.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Lugar de Trabajo
/
Contaminantes Ocupacionales del Aire
Idioma:
Zh
Revista:
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi
Asunto de la revista:
MEDICINA OCUPACIONAL
Año:
2021
Tipo del documento:
Article
País de afiliación:
China