Your browser doesn't support javascript.
loading
Real-Time Estimation of Aerobic Threshold and Exercise Intensity Distribution Using Fractal Correlation Properties of Heart Rate Variability: A Single-Case Field Application in a Former Olympic Triathlete.
Gronwald, Thomas; Berk, Sander; Altini, Marco; Mourot, Laurent; Hoos, Olaf; Rogers, Bruce.
Afiliación
  • Gronwald T; Faculty of Health Sciences, Department of Performance, Neuroscience, Therapy and Health, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Hamburg, Germany.
  • Berk S; Dutch Triathlon Federation, Arnhem, Netherlands.
  • Altini M; Faculty of Behavioral and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, Netherlands.
  • Mourot L; EA3920 Prognostic Factors and Regulatory Factors of Cardiac and Vascular Pathologies, Exercise Performance Health Innovation (EPHI) Platform, University of Bourgogne Franche-Comté, Besançon, France.
  • Hoos O; Division for Physical Education, National Research Tomsk Polytechnic University, Tomsk, Russia.
  • Rogers B; Center for Sports and Physical Education, Julius-Maximilians-University of Wuerzburg, Wuerzburg, Germany.
Front Sports Act Living ; 3: 668812, 2021.
Article en En | MEDLINE | ID: mdl-34124661
A non-linear heart rate variability (HRV) index based on fractal correlation properties called alpha1 of Detrended Fluctuation Analysis (DFA-alpha1), has been shown to change with endurance exercise intensity. Its unique advantage is that it provides information about current absolute exercise intensity without prior lactate or gas exchange testing. Therefore, real-time assessment of this metric during field conditions using a wearable monitoring device could directly provide a valuable exercise intensity distribution without prior laboratory testing for different applied field settings in endurance sports. Until of late no mobile based product could display DFA-alpha1 in real-time using off the shelf consumer products. Recently an app designed for iOS and Android devices, HRV Logger, was updated to assess DFA-alpha1 in real-time. This brief research report illustrates the potential merits of real-time monitoring of this metric for the purposes of aerobic threshold (AT) estimation and exercise intensity demarcation between low (zone 1) and moderate (zone 2) in a former Olympic triathlete. In a single-case feasibility study, three practically relevant scenarios were successfully evaluated in cycling, (1) estimation of a HRV threshold (HRVT) as an adequate proxy for AT using Kubios HRV software via a typical cycling stage test, (2) estimation of the HRVT during real-time monitoring using a cycling 6 min stage test, (3) a simulated 1 h training ride with enforcement of low intensity boundaries and real-time HRVT confirmation. This single-case field evaluation illustrates the potential of an easy-to-use and low cost real-time estimation of the aerobic threshold and exercise intensity distribution using fractal correlation properties of HRV. Furthermore, this approach may enhance the translation of science into endurance sports practice for future real-world settings.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Front Sports Act Living Año: 2021 Tipo del documento: Article País de afiliación: Alemania