Your browser doesn't support javascript.
loading
Hydration of Hydrophilic Cloth Face Masks Enhances the Filtration of Nanoparticles.
Zangmeister, Christopher D; Radney, James G; Staymates, Matthew E; Vicenzi, Edward P; Weaver, Jamie L.
Afiliación
  • Zangmeister CD; Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States.
  • Radney JG; Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States.
  • Staymates ME; Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States.
  • Vicenzi EP; Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States.
  • Weaver JL; Museum Conservation Institute, Smithsonian Institution, Suitland, Maryland 20746, United States.
ACS Appl Nano Mater ; 4(3): 2694-2701, 2021 Mar 26.
Article en En | MEDLINE | ID: mdl-34192243
ABSTRACT
Under high humidity conditions that mimic respiration, the filtration efficiency (FE) of hydrophilic fabrics increases when challenged with hygroscopic nanoparticles, for example, respiratory droplets containing SARS-CoV-2. The FE and differential pressure (ΔP) of natural, synthetic, and blended fabrics were measured as a function of relative humidity (RH) for particles with mobility diameters between 50 and 825 nm. Fabrics were equilibrated at 99% RH, mimicking conditions experienced when worn as a face mask. The FE increased after equilibration at 99% RH by a relative percentage of 33 ± 12% for fabrics composed of two layers of 100% cotton when challenged by 303 nm-mobility-diameter NaCl aerosol. The FE for samples of synthetics and polyester/cotton blends was unchanged upon equilibration at 99% RH. Increases in FE for 100% cotton fabrics were a function of particle size with a relative increase of 63% at the largest measured particle size (825 nm). The experimental results are consistent with increased particle capture due to H2O uptake and growth as the particles traverse the fabric.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: ACS Appl Nano Mater Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: ACS Appl Nano Mater Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos
...