Extracellular volume quantification using synthetic haematocrit assessed from native and post-contrast longitudinal relaxation T1 times of a blood pool.
Opatril, Lukas; Panovsky, Roman; Machal, Jan; Holecek, Tomas; Masarova, Lucia; Feitova, Vera; Kincl, Vladimir; Hodejovsky, Marek; Spinarova, Lenka.
Afiliación
  • Opatril L; 1st Department of Internal Medicine and Cardioangiology, St. Anne's University Hospital, Brno, Czech Republic.
  • Panovsky R; International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic.
  • Machal J; Faculty of Medicine, Masaryk University, Brno, Czech Republic.
  • Holecek T; 1st Department of Internal Medicine and Cardioangiology, St. Anne's University Hospital, Brno, Czech Republic. panovsky@fnusa.cz.
  • Masarova L; International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic. panovsky@fnusa.cz.
  • Feitova V; Faculty of Medicine, Masaryk University, Brno, Czech Republic. panovsky@fnusa.cz.
  • Kincl V; 1st Department of Internal Medicine and Cardioangiology, International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic. panovsky@fnusa.cz.
  • Hodejovsky M; International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic.
  • Spinarova L; Department of Pathophysiology, Faculty of Medicine, Masaryk University, Brno, Czech Republic.
BMC Cardiovasc Disord ; 21(1): 363, 2021 07 31.
Article en En | MEDLINE | ID: mdl-34330214
ABSTRACT

BACKGROUND:

In terms of cardiovascular magnetic resonance are haematocrit values required for calculation of extracellular volume fraction (ECV). Previously published studies have hypothesized that haematocrit could be calculated from T1 blood pool relaxation time, however only native T1 relaxation time values have been used and the resulting formulae had been both in reciprocal and linear proportion. The aim of the study was to generate a synthetic haematocrit formula from only native relaxation time values first, calculate whether linear or reciprocal model is more precise in haematocrit estimation and then determine whether adding post-contrast values further improve its precision.

METHODS:

One hundred thirty-nine subjects underwent CMR examination. Haematocrit was measured using standard laboratory methods. Afterwards T1 relaxation times before and after the application of a contrast agent were measured and a statistical relationship between these values was calculated.

RESULTS:

Different linear and reciprocal models were created to estimate the value of synthetic haematocrit and ECV. The highest coefficient of determination was observed in the combined reciprocal model "- 0.047 + (779/ blood native) - (11.36/ blood post-contrast)".

CONCLUSIONS:

This study provides more evidence that assessing synthetic haematocrit and synthetic ECV is feasible and statistically most accurate model to use is reciprocal. Adding post-contrast values to the calculation was proved to improve the precision of the formula statistically significantly.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Compuestos Organometálicos / Imagen por Resonancia Magnética / Medios de Contraste / Cardiopatías / Hematócrito / Miocardio Tipo de estudio: Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: BMC Cardiovasc Disord Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: República Checa

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Compuestos Organometálicos / Imagen por Resonancia Magnética / Medios de Contraste / Cardiopatías / Hematócrito / Miocardio Tipo de estudio: Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: BMC Cardiovasc Disord Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: República Checa
...