Influence of post-label delay time on the performance of 3D pseudo-continuous arterial spin labeling magnetic resonance imaging in the characterization of parotid gland tumors.
Hu, Hao; Chen, Lu; Zhu, Liu-Ning; Chen, Wei; Su, Guo-Yi; Dou, Weiqiang; Bu, Shou-Shan; Wu, Fei-Yun; Xu, Xiao-Quan.
Afiliación
  • Hu H; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Gulou District, Nanjing, People's Republic of China.
  • Chen L; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Gulou District, Nanjing, People's Republic of China.
  • Zhu LN; Department of Stomatology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, People's Republic of China.
  • Chen W; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Gulou District, Nanjing, People's Republic of China.
  • Su GY; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Gulou District, Nanjing, People's Republic of China.
  • Dou W; GE Healthcare, MR Research China, Beijing, People's Republic of China.
  • Bu SS; Department of Stomatology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, People's Republic of China.
  • Wu FY; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Gulou District, Nanjing, People's Republic of China. wfy_njmu@163.com.
  • Xu XQ; Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd, Gulou District, Nanjing, People's Republic of China. xiaoquanxu_1987@163.com.
Eur Radiol ; 32(2): 1087-1094, 2022 Feb.
Article en En | MEDLINE | ID: mdl-34347158
ABSTRACT

OBJECTIVE:

To evaluate the influence of post-label delay times (PLDs) on the performance of 3D pseudo-continuous arterial spin labeling (pCASL) magnetic resonance imaging for characterizing parotid gland tumors and to explore the optimal PLDs for the differential diagnosis. MATERIALS AND

METHOD:

Fifty-eight consecutive patients with parotid gland tumors were enrolled, including 33 patients with pleomorphic adenomas (PAs), 16 patients with Warthin's tumors (WTs), and 9 patients with malignant tumors (MTs). 3D pCASL was scanned for each patient five times, with PLDs of 1025 ms, 1525 ms, 2025 ms, 2525 ms, and 3025 ms. Tumor blood flow (TBF) was calculated, and compared among different PLDs and tumor groups. Performance of TBF at different PLDs was evaluated using receiver operating characteristic analysis.

RESULTS:

With an increasing PLD, TBF tended to gradually increase in PAs (p < 0.001), while TBF tended to slightly increase and then gradually decrease in WTs (p = 0.001), and PAs showed significantly lower TBF than WTs at all 5 PLDs (p < 0.05). PAs showed significantly lower TBF than MTs at 4 PLDs (p < 0.05), except at 3025 ms (p = 0.062). WTs showed higher TBF than MTs at all 5 PLDs; however, differences did not reach significance (p > 0.05). Setting a TBF of 64.350 mL/100g/min at a PLD of 1525 ms, or a TBF of 23.700 mL/100g/min at a PLD of 1025 ms as the cutoff values, optimal performance could be obtained for differentiating PAs from WTs (AUC = 0.905) or from MTs (AUC = 0.872).

CONCLUSIONS:

Short PLDs (1025 ms or 1525 ms) are suggested to be used in 3D pCASL for characterizing parotid gland tumors in clinical practice. KEY POINTS • With 5 different PLDs, 3D pCASL can reflect the variation of blood flow in parotid gland tumors. • 3D pCASL is useful for characterizing PAs from WTs or MTs. • Short PLDs (1025 ms or 1525 ms) are suggested to be used in 3D pCASL for characterizing parotid gland tumors in clinical practice.