Your browser doesn't support javascript.
loading
An inter-day assessment of the ABC parameters in the evaluation of progressive keratoconus.
Gustafsson, Ingemar; Faxén, Tove; Vicente, André; Bergström, Anders; Ivarsen, Anders; Hjortdal, Jesper Østergaard.
Afiliación
  • Gustafsson I; Department of Clinical Sciences, Ophthalmology, Lund University, Skåne University Hospital, Kioskgatan 1, 222 85, Lund, Sweden. gustafsson.ingemar@gmail.com.
  • Faxén T; Department of Clinical Sciences, Ophthalmology, Lund University, Skåne University Hospital, Kioskgatan 1, 222 85, Lund, Sweden.
  • Vicente A; Department of Clinical Sciences, Ophthalmology, Lund University, Skåne University Hospital, Kioskgatan 1, 222 85, Lund, Sweden.
  • Bergström A; Department of Clinical Sciences, Ophthalmology, Lund University, Skåne University Hospital, Kioskgatan 1, 222 85, Lund, Sweden.
  • Ivarsen A; Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark.
  • Hjortdal JØ; Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark.
Sci Rep ; 11(1): 16037, 2021 08 06.
Article en En | MEDLINE | ID: mdl-34362986
ABSTRACT
The progression of keratoconus is commonly determined by comparing the results of corneal tomographic measurements on different occasions. However, investigations on the repeatability of measurements are commonly performed within the same day, thus not taking the inter-day variation into account. The effect of keratoconus disease severity on the measurement error is also seldom considered. In this post hoc investigation, the parameters A, B and C in the Belin ABCD Progression Display were evaluated in relation to disease severity in intra-day and inter-day measurements. Four consecutive measurements were performed on 61 patients with keratoconus on the same day (intra-day). In another cohort, four consecutive measurements were obtained and then repeated 3 days later in 25 patients with keratoconus and 25 healthy controls (inter-day). The results suggest that the diagnosis of disease progression would benefit from inter-day measurements, and the stratification of the parameters A and C according to disease severity. It is also recommended that tomographic systems such as the Pentacam HR be modified to allow the comparison of both single measurements and the mean of replicate measurements of the parameters used in the assessment of progression of keratoconus.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Índice de Severidad de la Enfermedad / Córnea / Topografía de la Córnea / Paquimetría Corneal / Queratocono Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Año: 2021 Tipo del documento: Article País de afiliación: Suecia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Índice de Severidad de la Enfermedad / Córnea / Topografía de la Córnea / Paquimetría Corneal / Queratocono Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Año: 2021 Tipo del documento: Article País de afiliación: Suecia
...