Your browser doesn't support javascript.
loading
Feasibility of Subtraction Coronary Computed Tomographic Angiography and Influencing Factor Analysis: a Retrospective Study.
Huang, Chao; Wan, Wei-Jia; Yao, Yu-Huan; Xia, Li-Ming; Huang, Wen-Hua.
Afiliación
  • Huang C; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Wan WJ; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Yao YH; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Xia LM; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Huang WH; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. 1551858438@qq.com.
Curr Med Sci ; 41(4): 821-826, 2021 Aug.
Article en En | MEDLINE | ID: mdl-34403108
ABSTRACT

OBJECTIVE:

To investigate the feasibility of subtraction coronary computed tomographic (CT) angiography (SubCCTA) to decline calcium artifacts and improve diagnostic accuracy in the presence of coronary calcification and analyze the factors that influence SubCCTA.

METHODS:

A total of 294 patients suspected of having coronary artery diseases underwent coronary computed tomographic angiography (CCTA) and SubCCTA. Coronary stenoses were blindly evaluated by two experienced radiologists, which were compared with invasive coronary angiography (ICA). Multiple statistical indexes were adopted to analyze the value of SubCCTA for the diagnosis of calcium stenoses.

RESULTS:

The diagnosable rate of SubCCTA was 67.2% (n=197), and the non-diagnosable rate was 32.8% (n=97). Using SubCCTA, the false positive rate decreased from 56.5% to 17.4%, and the corresponding diagnostic accuracy was increased from 83.6% to 92.9%. Univariate logistic regression analysis showed that height (OR=1.029, 95% CI=1.001-1.058), weight (OR=1.025, 95% CI=1.004-1.046), left ventricular size (OR=1.018, 95% CI=1.007-1.030), cardiothoracic ratio (OR=39.917, 95% CI=1.244-1281.098), the average heart rate (OR=0.866, 95% CI=0.836-0.896) and heart rate range (OR=0.882, 95% CI=0.853-0.912) might be the factors influencing SubCCTA.

CONCLUSION:

This study suggested that SubCCTA could help improve diagnostic accuracy in the presence of calcium plaques. Moreover, several factors were discovered for the first time to possibly influence SubCCTA, which will be helpful in improving the subtracted image quality.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Angiografía de Substracción Digital / Estenosis Coronaria / Angiografía por Tomografía Computarizada Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Curr Med Sci Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Angiografía de Substracción Digital / Estenosis Coronaria / Angiografía por Tomografía Computarizada Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Curr Med Sci Año: 2021 Tipo del documento: Article País de afiliación: China
...