On-line solid-phase extraction of pharmaceutical compounds from wastewater treatment plant samples using restricted access media in column-switching liquid chromatography-tandem mass spectrometry.
Marasco Júnior, César A; Sartore, Douglas M; Lamarca, Rafaela S; da Silva, Bianca F; Santos-Neto, Álvaro J; Lima Gomes, Paulo Clairmont F de.
Afiliación
  • Marasco Júnior CA; National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP), P.O. Box 355, 14800-060 Araraquara, São Paulo, Brazil.
  • Sartore DM; São Carlos Institute of Chemistry, University of São Paulo (USP), 13566-590 São Carlos, São Paulo, Brazil.
  • Lamarca RS; National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP), P.O. Box 355, 14800-060 Araraquara, São Paulo, Brazil.
  • da Silva BF; National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP), P.O. Box 355, 14800-060 Araraquara, São Paulo, Brazil; College of Veterinary Medicine, Dep
  • Santos-Neto ÁJ; São Carlos Institute of Chemistry, University of São Paulo (USP), 13566-590 São Carlos, São Paulo, Brazil.
  • Lima Gomes PCF; National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP), P.O. Box 355, 14800-060 Araraquara, São Paulo, Brazil. Electronic address: paulo.clairmont
Article en En | MEDLINE | ID: mdl-34416677
ABSTRACT
An on-line solid phase extraction using a lab-made restricted access media (RAM) was developed as sample preparation procedure for determination of the pharmaceutical compounds caffeine (CAF), carbamazepine (CBZ), norfloxacin (NOR), ciprofloxacin (CIP), fluoxetine (FLX) and venlafaxine in wastewater treatment plant samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS). This method is suitable for use in routine of analysis, avoiding cross-contamination and requiring only a small sample volume (50 µL), with minimal handling. The method was validated according to international guidelines. The chromatographic efficiency was evaluated using peak resolution and asymmetry parameters. Carryover was also evaluated, in order to ensure reliability of the analysis and the ability to reuse the cartridge. Satisfactory linearity (r2 > 0.99) was obtained for all the compounds. The intra- and inter-day precision values were lower than 5.79 and 14.1%, respectively. The limits of detection ranged from 0.01 to 3 µg L-1 and the limits of quantification were from 0.1 to 5 µg L-1. The method was applied to 20 environmental wastewater samples, with caffeine being the most widely detected compound, at the highest concentration of 392 µg L-1, while other compounds were detected in fewer samples at lower concentrations (up to 9.60 µg L-1). The lab-made modification is a cheaper option for on-line sample preparation, compared to commercially available on-line SPE cartridges and RAM columns. Moreover, a high-throughput procedure was achieved, with an analysis time of 16 min including sample preparation and chromatographic separation. The same RAM column was applied over 200 injections including method optimization, validation and application in wastewater samples without loss of analytical response.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_medicamentos_vacinas_tecnologias Asunto principal: Contaminantes Químicos del Agua / Preparaciones Farmacéuticas / Cromatografía Liquida / Espectrometría de Masas en Tándem / Extracción en Fase Sólida Tipo de estudio: Guideline / Prognostic_studies Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2021 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_medicamentos_vacinas_tecnologias Asunto principal: Contaminantes Químicos del Agua / Preparaciones Farmacéuticas / Cromatografía Liquida / Espectrometría de Masas en Tándem / Extracción en Fase Sólida Tipo de estudio: Guideline / Prognostic_studies Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2021 Tipo del documento: Article País de afiliación: Brasil
...