Your browser doesn't support javascript.
loading
Differences in human and minipig platelet number, volume and activation induced by borosilicate glass beads in a modified chandler loop-system.
Greif, G; Mrowietz, C; Wendt, M; Jung, F; Hiebl, B; Meyer-Sievers, H.
Afiliación
  • Greif G; Institute for Animal Hygiene, Animal Welfare and Farm Animal Behavior, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany.
  • Mrowietz C; Institute for Animal Hygiene, Animal Welfare and Farm Animal Behavior, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany.
  • Wendt M; Clinic for Swine and Small Ruminants, Forensic Medicine and Ambulatory Service, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany.
  • Jung F; Brandenburg University of Technology, Cottbus-Senftenberg, Germany.
  • Hiebl B; Institute for Animal Hygiene, Animal Welfare and Farm Animal Behavior, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany.
  • Meyer-Sievers H; Institute for Animal Hygiene, Animal Welfare and Farm Animal Behavior, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany.
Clin Hemorheol Microcirc ; 79(1): 149-155, 2021.
Article en En | MEDLINE | ID: mdl-34487038
ABSTRACT
The pig is the most widely used large animal model in Europe, with cardiovascular research being one of the main areas of application. Adequate refinement of interventional studies in this field, meeting the requirements of Russel and Burchs' 3 R concept, can only be performed if blood-contacting medical devices are hemocompatible. Because most medical devices for cardiovascular interventional procedures are developed for humans they are tested mostly for compatibility with human blood. The aim of this study was therefore to determine whether there are differences in behavior of porcine and human platelets when they come into contact with glass, which was used as an exemplary thrombogenic material. For this purpose changes of platelet count, platelet volume and platelet expression of the activation markers CD61, CD62P and CD63 were measured using a modified chandler loop-system simulating the fluidic effects of the blood flow. Minipig and human platelets showed significant differences in number and volume, but not in activation after 4-8 min exposure to glass.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Plaquetas / Activación Plaquetaria Límite: Animals / Humans Idioma: En Revista: Clin Hemorheol Microcirc Asunto de la revista: ANGIOLOGIA / HEMATOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Plaquetas / Activación Plaquetaria Límite: Animals / Humans Idioma: En Revista: Clin Hemorheol Microcirc Asunto de la revista: ANGIOLOGIA / HEMATOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania
...