Analysis of Neural Interface When Using Modiolar Electrode Stimulation. Radiological Evaluation, Trans-Impedance Matrix Analysis and Effect on Listening Effort in Cochlear Implantation.
Ramos-de-Miguel, Angel; Falcón-González, Juan Carlos; Ramos-Macias, Angel.
Afiliación
  • Ramos-de-Miguel A; Hearing and Balance Laboratory, Las Palmas de Gran Canaria University (SIANI), 35001 Las Palmas, Spain.
  • Falcón-González JC; Department of Otolaryngology, Head and Neck Surgery, Complejo Hospitalario Universitario Insular Materno Infantil de Gran Canaria, 35016 Las Palmas, Spain.
  • Ramos-Macias A; Hearing and Balance Laboratory, Las Palmas de Gran Canaria University (SIANI), 35001 Las Palmas, Spain.
J Clin Med ; 10(17)2021 Aug 31.
Article en En | MEDLINE | ID: mdl-34501410
BACKGROUND: The proximity of the electrode to the modiolar wall may be of interest to investigate the effect of pitch discrimination. This research establishes the relation between these factors and whether perimodiolar positions may provide benefits regarding improved electrode discrimination. METHODS: A prospective randomized study including 24 post-lingual deaf adults was performed. A psychoacoustic study was done by using a psychoacoustic research platform. Radiological study, and a cone-beam computed tomography was used to assess post cochlear implantation electrodes' position. Trans-impedance matrix (TIM) analysis was performed after cochlear implant insertion in all cases, and pupillometry test was also performed. RESULTS: 12 patients received a slim perimodiolar electrode array, and 12 patients received a straight electrode array. Although all the patients showed similar speech test results after 12 months follow-up, those implanted with a perimodiolar electrode obtained better scores in electrode discrimination test and pupillometry test, and showed more homogenous TIM patterns. CONCLUSIONS: The better positioning of the electrode array seams to provide a better hearing resolution and less listening effort trans-impedance matrix seems to be a useful tool to analyze positioning of the perimodiolar array.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Clinical_trials Idioma: En Revista: J Clin Med Año: 2021 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Clinical_trials Idioma: En Revista: J Clin Med Año: 2021 Tipo del documento: Article País de afiliación: España
...