Your browser doesn't support javascript.
loading
The heparinase-linked differential time method allows detection of heparin potency in whole blood with high sensitivity and dynamic range.
Zheng, Anran; Zhang, Wei; Li, Chao; Guo, Zhen; Li, Chuanyu; Zhang, Changsong; Yao, Jia; Zhang, Zhiqi; Li, Jinze; Zhao, Shasha; Zhou, Lianqun.
Afiliación
  • Zheng A; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Chin
  • Zhang W; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Chin
  • Li C; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Chin
  • Guo Z; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Chin
  • Li C; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Chin
  • Zhang C; Department of Laboratory Medicine, The Affiliated Suzhou Science and Technology Town Hospital, Nanjing Medical University, Suzhou 215153, Jiangsu Province, China.
  • Yao J; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Chin
  • Zhang Z; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Chin
  • Li J; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Chin
  • Zhao S; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, China.
  • Zhou L; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Chin
Biosens Bioelectron ; 198: 113856, 2022 Feb 15.
Article en En | MEDLINE | ID: mdl-34871836
Anticoagulation therapy with heparin is an effective treatment against thrombosis. Heparin tends to cause spontaneous bleeding and requires regular monitoring during therapy. Most high-sensitivity heparin sensors have focused on the concentration detection in clarified buffer solution. However, the pharmacodynamics of heparin vary depending on individual patient or disease, while potency detection with high sensitivity and dynamic range outperforms concentration detection in clinical diagnosis. In this study, a novel heparinase-linked differential time (HLDT) method was established with a two-zone of Graphene modified Carbon (GR-C) sensor, which was utilized to evaluate heparin potency in whole blood. It was based on electrochemical measurement of clotting time shifting associated with presence or absence of heparinase. Heparinase inhibits the anticoagulant ability of heparin by forming a heparin-antithrombin-thrombin complex during coagulation. And the intensity and peak time of electrochemical current were associated with thrombin activity and clotting on the electrode. The results demonstrated that the sensor had high selectivity for heparin potency in 10 µL of whole blood with a detection limit of 0.1 U/mL, and the linear detection range was 0.1-5 U/mL. The coefficient of variation (CV) of the peak time was less than 5%, and linear correlation between the GR-C sensor and the TEG-5000 instrument was 0.987. Thus, the HLDT method has better clinical application due to its good repeatability, high sensitivity and wide range in heparin potency evaluation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Heparina / Técnicas Biosensibles Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Heparina / Técnicas Biosensibles Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2022 Tipo del documento: Article
...