Your browser doesn't support javascript.
loading
Use of computer tomography imaging for analyzing bone remodeling around a percutaneous osseointegrated implant.
Wankier, Zakary; Taylor, Carolyn; Drew, Alex; Kubiak, Erik; Agarwal, Jayant; Sinclair, Sarina.
Afiliación
  • Wankier Z; Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA.
  • Taylor C; Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA.
  • Drew A; Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA.
  • Kubiak E; Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA.
  • Agarwal J; Department of Orthopedic Surgery, University of Nevada Las Vegas, Las Vegas, Nevada, USA.
  • Sinclair S; George E. Wahlen Department of Veterans Affairs Medical Center, Salt Lake City, Utah, USA.
J Orthop Res ; 40(9): 2065-2075, 2022 09.
Article en En | MEDLINE | ID: mdl-34910325
ABSTRACT
Osseointegration (OI) is being used for the direct skeletal attachment of prosthetic limbs using an intramedullary stem that extends percutaneously from the subject's residual limb. For this technology to be successful, bone ingrowth and remodeling around the implant must occur. Physicians need an effective way to assess bone remodeling to make informed treatment and rehabilitation decisions. Previous studies utilizing two-dimensional imaging X-ray as a tool to monitor bone-remodeling around OI devices have limitations. This study describes methodology that was developed utilizing computed tomography (CT) imaging as a tool for analyzing bone remodeling around a percutaneous OI implant. Six transfemoral amputees implanted with a percutaneous osseointegrated prosthesis (POP) had CT scans taken of their residual femur at 6 and 52 weeks postoperatively. Three-dimensional femoral models were processed using custom MATLAB script to collect cortical and medullary morphology measurements. Morphology data from 6- and 52-week scans were compared to quantify bone remodeling around the POP implant. Fifty-two weeks after implantation of the POP device, increases in cortical bone area and thickness were observed around the porous-coated stem. Minimal changes were observed in the medullary canal parameters within the periprosthetic regions. This study successfully utilized CT imaging and three-dimensional modeling techniques to analyze longitudinal data of bone remodeling around a transfemoral percutaneous implant. These methods have the potential to be used as a clinical tool for evaluating orthopedic implants in vivo. Data collected suggests that the POP device achieved the desired bone remodeling around the porous-coated region of the implanted stem.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Miembros Artificiales / Prótesis Anclada al Hueso Tipo de estudio: Prognostic_studies Idioma: En Revista: J Orthop Res Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Miembros Artificiales / Prótesis Anclada al Hueso Tipo de estudio: Prognostic_studies Idioma: En Revista: J Orthop Res Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos
...