Your browser doesn't support javascript.
loading
Visualization of Anterior Chamber Angle Structures With Scattering- and Polarization-Sensitive Anterior Segment Optical Coherence Tomography.
Ueno, Yuta; Mori, Haruhiro; Kikuchi, Keita; Yamanari, Masahiro; Oshika, Tetsuro.
Afiliación
  • Ueno Y; Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan.
  • Mori H; Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan.
  • Kikuchi K; Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan.
  • Yamanari M; Department of Technological Development, Tomey Corporation, Nagoya, Japan.
  • Oshika T; Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan.
Transl Vis Sci Technol ; 10(14): 29, 2021 12 01.
Article en En | MEDLINE | ID: mdl-34964836
Purpose: The purpose of this study was to compare three optical coherence tomography (OCT) modalities in the observation of anterior chamber angle structures; trabecular meshwork (TM), Schlemm's canal (SC), and band of extracanalicular limbal lamina (BELL). Methods: Three OCT modalities were used: (1) 2 × 2 Jones-matrix scattering OCT (S-OCT) representing conventional intensity OCT, (2) polarization-diverse S-OCT that was calculated as summation of all elements of the Jones-matrix to eliminate the influence of artifacts caused by sample birefringence, and (3) polarization-sensitive OCT (PS-OCT) to assess depth-resolved phase retardation. Results: In a total of 97 eyes of 55 subjects, nasal and temporal angles were scanned. The detection rate of TM and BELL was significantly different among modalities; highest with PS-OCT (95.1% and 99.2%), followed by 2 × 2 Jones-matrix S-OCT (71.1% and 88.7%) and polarization-diverse S-OCT (33.2% and 25.0%), indicating the influence of artifacts on 2 × 2 Jones-matrix S-OCT measurements. SC was visible with 2 × 2 Jones-matrix S-OCT, polarization-diverse S-OCT, and PS-OCT in 14.2%, 14.9%, and 0.3% of images, respectively. The intergrader agreement as evaluated with the prevalence-adjusted bias-adjusted κ value was higher with PS-OCT than with other S-OCTs. Conclusions: Visibility of anterior chamber angle structures was assessed with three OCT modalities. For TM and BELL that are rich in collagen fibers, PS-OCT provides significantly better visibility than S-OCT without the influence of artifacts arising from polarization or birefringence. Visualization of SC was more difficult with any OCT modalities. Translational Relevance: PS-OCT is a useful tool to investigate the anterior chamber angle structures which are difficult to observe with conventional OCT.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía de Coherencia Óptica / Cámara Anterior Tipo de estudio: Diagnostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Transl Vis Sci Technol Año: 2021 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía de Coherencia Óptica / Cámara Anterior Tipo de estudio: Diagnostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Transl Vis Sci Technol Año: 2021 Tipo del documento: Article País de afiliación: Japón
...