Your browser doesn't support javascript.
loading
Proximal true lumen collapse in a chronic type B aortic dissection patient: A case report.
Zhang, Li; Guan, Wei-Kang; Wu, Hua-Ping; Li, Xiang; Lv, Kai-Ping; Zeng, Cun-Liang; Song, Huan-Huan; Ye, Qian-Ling.
Afiliación
  • Zhang L; Department of Vascular Surgery, Dazhou Central Hosptial, Dazhou 0833, Sichuan Province, China. 50328731@qq.com.
  • Guan WK; Department of Vascular Surgery, Dazhou Central Hosptial, Dazhou 0833, Sichuan Province, China.
  • Wu HP; Department of Vascular Surgery, Dazhou Central Hosptial, Dazhou 0833, Sichuan Province, China.
  • Li X; Department of Vascular Surgery, Dazhou Central Hosptial, Dazhou 0833, Sichuan Province, China.
  • Lv KP; Department of Vascular Surgery, Dazhou Central Hosptial, Dazhou 0833, Sichuan Province, China.
  • Zeng CL; Department of Vascular Surgery, Dazhou Central Hosptial, Dazhou 0833, Sichuan Province, China.
  • Song HH; Department of Vascular Surgery, Dazhou Central Hosptial, Dazhou 0833, Sichuan Province, China.
  • Ye QL; Department of Vascular Surgery, Dazhou Central Hosptial, Dazhou 0833, Sichuan Province, China.
World J Clin Cases ; 9(34): 10689-10695, 2021 Dec 06.
Article en En | MEDLINE | ID: mdl-35005002
ABSTRACT

BACKGROUND:

In the context of aortic dissection, increasing pressure within the newly formed false lumen can result in the progressive compression of the true aortic channel. However, true lumen collapse in chronic type B aortic dissection (cTBAD) patients is rare, with few clinical or experimental studies to date having explored the causes of such collapse. CASE

SUMMARY:

In the present report, we describe a rare case of true-lumen collapse in an 83-year-old patient diagnosed with cTBAD, and we discuss potential therapeutic interventions for such cases. Following thoracic endovascular aortic repair (TEVAR), computed tomography angiography revealed satisfactory stent-graft positioning, no endoleakage, true lumen enlargement, thrombus formation in the false lumen, and slight enlargement of the true lumen distal to the stent-graft. Computational hemodynamic analyses indicated that the wall shear stress and pressure within the false lumen were significantly reduced following TEVAR.

CONCLUSION:

TEVAR treatment of cTBAD patients suffering from proximal true lumen collapse can facilitate some degree of effective remodeling.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: World J Clin Cases Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: World J Clin Cases Año: 2021 Tipo del documento: Article País de afiliación: China
...