[Value of radiomics model based on dynamic contrast-enhanced magnetic resonance imaging in differentiation fat-poor angiomyolipoma from alpha-fetoprotein-negative hepatocellular carcinoma in the background of non-cirrhotic liver].
Zhonghua Yi Xue Za Zhi
; 102(3): 196-200, 2022 Jan 18.
Article
en Zh
| MEDLINE
| ID: mdl-35042288
Objective: To explore the value of radiomics model based on dynamic contrast-enhanced magnetic resonance imaging (MRI) in differentiation fat-poor angiomyolipoma (fp-AML) from alpha-fetoprotein-negative hepatocellular carcinoma (n-HCC) in the background of non-cirrhotic liver. Methods: The complete data of 121 patients from Guangdong Provincial People's Hospital, Zhongshan Hospital Affiliated to Fudan University and Sun Yat-sen University Cancer Center with hepatic fp-AML and n-HCC confirmed by pathology from October 2010 to July 2020 were retrospectively analyzed. Among them, 75 were males and 46 were females, aged from 23 to 80 (55±12) years. A total of 93 patients from Zhongshan Hospital Affiliated to Fudan University were divided into the training cohort (n=75) and internal test cohort (n=18) according to entry time, and the patients of other 2 hospitals were divided into external test cohort (n=28). The radiomics features were extracted from the preoperative triple-phase contrast-enhanced images. The feature selection algorithm based on Joint Mutual Information Maximisation (JMIM) was used to extract the optimal feature subset, and support vector machine (SVM) was used to build the radiomics model. The diagnostic performance of radiomics model was evaluated using the receiver operating characteristic (ROC) curve, and was compared with that of two radiologists. Results: In the internal cohort, the area under the curve (AUC) for the differential diagnosis between fp-AML and n-HCC of the radiomics model was 0.819 (with an accuracy of 72.2%), outperforming than radiologist 1 with 10 years of diagnostic experience (AUC=0.542, P=0.029) and radiologist 2 with 2 years of diagnostic experience (AUC=0.375, P=0.004). In the external cohort, the AUC of the radiomics model was 0.772 (with and accuracy of 71.4%), which was comparable to that of radiologist 1 (AUC=0.661, P=0.442) and better than that of radiologist 2 (AUC=0.400, P=0.008). Conclusion: The radiomics model based on dynamic contrast-enhanced MRI is of high accuracy for preoperatively differentiating hepatic fp-AML from n-HCC in the noncirrhotic liver.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Angiomiolipoma
/
Carcinoma Hepatocelular
/
Neoplasias Hepáticas
Tipo de estudio:
Observational_studies
/
Prognostic_studies
Límite:
Adult
/
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
Zh
Revista:
Zhonghua Yi Xue Za Zhi
Año:
2022
Tipo del documento:
Article
País de afiliación:
China