Your browser doesn't support javascript.
loading
Peroral Cholangioscopy-Guided Targeted Biopsy versus Conventional Endoscopic Transpapillary Forceps Biopsy for Biliary Stricture with Suspected Bile Duct Cancer.
Sekine, Katsunori; Yasuda, Ichiro; Doi, Shinpei; Kuniyoshi, Noriyuki; Tsujikawa, Takayuki; Takano, Yuichi; Mabuchi, Masatoshi; Takahashi, Kosuke; Kawamoto, Masashi; Takahashi, Mikiko; Aso, Tatsuya; Miyazaki, Tatsuhiko; Iwashita, Takuji.
Afiliación
  • Sekine K; Department of Gastroenterology, Teikyo University Mizonokuchi Hospital, Kawasaki 213-8507, Japan.
  • Yasuda I; Department of Gastroenterology, Teikyo University Mizonokuchi Hospital, Kawasaki 213-8507, Japan.
  • Doi S; Third Department of Internal Medicine, University of Toyama, Toyama 930-0194, Japan.
  • Kuniyoshi N; Department of Gastroenterology, Teikyo University Mizonokuchi Hospital, Kawasaki 213-8507, Japan.
  • Tsujikawa T; Department of Gastroenterology, Teikyo University Mizonokuchi Hospital, Kawasaki 213-8507, Japan.
  • Takano Y; Department of Gastroenterology, Teikyo University Mizonokuchi Hospital, Kawasaki 213-8507, Japan.
  • Mabuchi M; Department of Gastroenterology, Teikyo University Mizonokuchi Hospital, Kawasaki 213-8507, Japan.
  • Takahashi K; Department of Gastroenterology, Teikyo University Mizonokuchi Hospital, Kawasaki 213-8507, Japan.
  • Kawamoto M; Third Department of Internal Medicine, University of Toyama, Toyama 930-0194, Japan.
  • Takahashi M; Department of Diagnostic Pathology, Teikyo University Mizonokuchi Hospital, Kawasaki 213-8507, Japan.
  • Aso T; Department of Diagnostic Pathology, Teikyo University Mizonokuchi Hospital, Kawasaki 213-8507, Japan.
  • Miyazaki T; Department of Diagnostic Pathology, Teikyo University Mizonokuchi Hospital, Kawasaki 213-8507, Japan.
  • Iwashita T; Department of Pathology, Gifu University Hospital, Gifu 501-1194, Japan.
J Clin Med ; 11(2)2022 Jan 06.
Article en En | MEDLINE | ID: mdl-35053987
BACKGROUND: The recent improvement of peroral cholangioscopy (POCS) maneuverability has enabled the precise, targeted biopsy of bile duct lesions under direct cholangioscopic vision. However, as only small-cup biopsy forceps can pass through the scope channel, the resulting small sample size may limit the pathological diagnosis of biopsy specimens. This study compared the diagnostic abilities of POCS-guided biopsy and conventional fluoroscopy-guided biopsy for bile duct cancer. METHOD: This multicenter, retrospective cohort study included patients exhibiting bile duct stricture with suspected cholangiocarcinoma in whom POCS-guided and fluoroscopy-guided biopsies were performed in the same session. The primary endpoint was the diagnostic sensitivity for malignancy. The size and quality of the biopsy specimens were also compared. RESULT: A total of 59 patients were enrolled. The sensitivity of POCS-guided biopsy was similar to that of fluoroscopy-guided biopsy (54.0% and 64.0%, respectively). However, when the modalities were combined, the sensitivity increased to 80.0%. The mean specimen size from POCS-guided biopsy was significantly smaller than that from fluoroscopy-guided biopsy. The specimen quality using fluoroscopy-guided biopsy was also better than that using POCS-guided biopsy. CONCLUSIONS: The diagnostic sensitivity of POCS-guided biopsy is still insufficient, mainly because of the limited specimen quantity and quality. Therefore, conventional fluoroscopy-guided biopsy would be helpful to improve diagnostic sensitivity.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Clinical_trials / Observational_studies Idioma: En Revista: J Clin Med Año: 2022 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Clinical_trials / Observational_studies Idioma: En Revista: J Clin Med Año: 2022 Tipo del documento: Article País de afiliación: Japón
...