Your browser doesn't support javascript.
loading
Near-Infrared Spectroscopy (NIRS) versus Hyperspectral Imaging (HSI) to Detect Flap Failure in Reconstructive Surgery: A Systematic Review.
Lindelauf, Anouk A M A; Saelmans, Alexander G; van Kuijk, Sander M J; van der Hulst, René R W J; Schols, Rutger M.
Afiliación
  • Lindelauf AAMA; Department of Cardiothoracic Surgery, Maastricht University Medical Center, Debyelaan 25, P.O. Box 5800, 6202 AZ Maastricht, The Netherlands.
  • Saelmans AG; Department of Cardiothoracic Surgery, Maastricht University Medical Center, Debyelaan 25, P.O. Box 5800, 6202 AZ Maastricht, The Netherlands.
  • van Kuijk SMJ; Department of Plastic, Reconstructive and Hand Surgery, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands.
  • van der Hulst RRWJ; Department of Clinical Epidemiology and Medical Technology Assessment, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands.
  • Schols RM; Department of Plastic, Reconstructive and Hand Surgery, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands.
Life (Basel) ; 12(1)2022 Jan 03.
Article en En | MEDLINE | ID: mdl-35054458
ABSTRACT
Rapid identification of possible vascular compromise in free flap reconstruction to minimize time to reoperation improves achieving free flap salvage. Subjective clinical assessment, often complemented with handheld Doppler, is the golden standard for flap monitoring; but this lacks consistency and may be variable. Non-invasive optical methods such as near-infrared spectroscopy (NIRS) and hyperspectral imaging (HSI) could facilitate objective flap monitoring. A systematic review was conducted to compare NIRS with HSI in detecting vascular compromise in reconstructive flap surgery as compared to standard monitoring. A literature search was performed using PubMed and Embase scientific database in August 2021. Studies were selected by two independent reviewers. Sixteen NIRS and five HSI studies were included. In total, 3662 flap procedures were carried out in 1970 patients using NIRS. Simultaneously; 90 flaps were performed in 90 patients using HSI. HSI and NIRS flap survival were 92.5% (95% CI 83.3-96.8) and 99.2% (95% CI 97.8-99.7). Statistically significant differences were observed in flap survival (p = 0.02); flaps returned to OR (p = 0.04); salvage rate (p < 0.01) and partial flap loss rate (p < 0.01). However, no statistically significant difference was observed concerning flaps with vascular crisis (p = 0.39). NIRS and HSI have proven to be reliable; accurate and user-friendly monitoring methods. However, based on the currently available literature, no firm conclusions can be drawn concerning non-invasive monitoring technique superiority.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies / Systematic_reviews Idioma: En Revista: Life (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies / Systematic_reviews Idioma: En Revista: Life (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Países Bajos
...