Your browser doesn't support javascript.
loading
MRI-based synthetic CT of the hip: can it be an alternative to conventional CT in the evaluation of osseous morphology?
Morbée, Lieve; Chen, Min; Van Den Berghe, Thomas; Schiettecatte, Eva; Gosselin, Robert; Herregods, Nele; Jans, Lennart B O.
Afiliación
  • Morbée L; Department of Radiology, Ghent University Hospital, Corneel Heymanslaan 10, 9000, Ghent, Belgium. lieve.morbee@uzgent.be.
  • Chen M; Department of Radiology, Ghent University Hospital, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
  • Van Den Berghe T; Department of Radiology, Ghent University Hospital, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
  • Schiettecatte E; Department of Radiology, Ghent University Hospital, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
  • Gosselin R; Department of Radiology, Ghent University Hospital, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
  • Herregods N; Department of Radiology, Ghent University Hospital, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
  • Jans LBO; Department of Radiology, Ghent University Hospital, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
Eur Radiol ; 32(5): 3112-3120, 2022 May.
Article en En | MEDLINE | ID: mdl-35066635
ABSTRACT

OBJECTIVES:

MRI is the gold standard for soft tissue evaluation in the hip joint. However, CT is superior to MRI in providing clear visualization of bony morphology. The aim of this study is to test the equivalency of MRI-based synthetic CT to conventional CT in quantitatively assessing bony morphology of the hip. MATERIALS AND

METHODS:

A prospective study was performed. Adult patients who underwent MRI and CT of the hips were included. Synthetic CT images were generated from MRI using a deep learning-based image synthesis method. Two readers independently performed clinically relevant measurements for hip morphology, including anterior and posterior acetabular sector angle, acetabular version angle, joint space width, lateral center-edge angle, sharp angle, alpha angle, and femoral head-neck offset on synthetic CT and CT. Inter-method, inter-reader, and intra-reader reliability and agreement were assessed using calculations of intraclass correlation coefficient, standard error of measurement, and smallest detectable change. The equivalency among CT and synthetic CT was evaluated using equivalency statistical testing.

RESULTS:

Fifty-four hips from twenty-seven participants were included. There was no reported hip pathology in the subjects. The observed agreement based on reliability and agreement parameters indicated a strong degree of concordance between CT and synthetic CT. Equivalence statistical testing showed that all synthetic CT measurements are equivalent to the CT measurements at the considered margins.

CONCLUSION:

In healthy individuals, we demonstrated equivalency of MRI-based synthetic CT to conventional CT for the quantitative evaluation of osseous hip morphology, thus obviating the radiation exposure of a pelvic CT examination. KEY POINTS •MRI-based synthetic CT images can be generated from MRI using a deep learning-based image synthesis method. •MRI-based synthetic CT is equivalent to CT in the quantitative assessment of bony hip morphology in healthy individuals. •MRI-based synthetic CT is promising for use in preoperative diagnosis and surgery planning.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Articulación de la Cadera Tipo de estudio: Observational_studies Límite: Adult / Humans Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Bélgica

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Articulación de la Cadera Tipo de estudio: Observational_studies Límite: Adult / Humans Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Bélgica
...