Your browser doesn't support javascript.
loading
In vivo melanin 3D quantification and z-epidermal distribution by multiphoton FLIM, phasor and Pseudo-FLIM analyses.
Pena, Ana-Maria; Decencière, Etienne; Brizion, Sébastien; Sextius, Peggy; Koudoro, Serge; Baldeweck, Thérèse; Tancrède-Bohin, Emmanuelle.
Afiliación
  • Pena AM; L'Oréal Research and Innovation, 1 Avenue Eugène Schueller, BP22, 93601, Aulnay-sous-Bois, France. ana-maria.pena@rd.loreal.com.
  • Decencière E; MINES ParisTech - PSL Research University, Fontainebleau, France.
  • Brizion S; L'Oréal Research and Innovation, 1 Avenue Eugène Schueller, BP22, 93601, Aulnay-sous-Bois, France.
  • Sextius P; L'Oréal Research and Innovation, 1 Avenue Eugène Schueller, BP22, 93601, Aulnay-sous-Bois, France.
  • Koudoro S; MINES ParisTech - PSL Research University, Fontainebleau, France.
  • Baldeweck T; L'Oréal Research and Innovation, 1 Avenue Eugène Schueller, BP22, 93601, Aulnay-sous-Bois, France.
  • Tancrède-Bohin E; L'Oréal Research and Innovation, Campus Charles Zviak RIO, 9 rue Pierre Dreyfus, Clichy, France.
Sci Rep ; 12(1): 1642, 2022 01 31.
Article en En | MEDLINE | ID: mdl-35102172
ABSTRACT
Characterizing melanins in situ and determining their 3D z-epidermal distribution is paramount for understanding physiological/pathological processes of melanin neosynthesis, transfer, degradation or modulation with external UV exposure or cosmetic/pharmaceutical products. Multiphoton fluorescence intensity- and lifetime-based approaches have been shown to afford melanin detection, but how can one quantify melanin in vivo in 3D from multiphoton fluorescence lifetime (FLIM) data, especially since FLIM imaging requires long image acquisition times not compatible with 3D imaging in a clinical setup? We propose an approach combining (i) multiphoton FLIM, (ii) fast image acquisition times, and (iii) a melanin detection method called Pseudo-FLIM, based on slope analysis of autofluorescence intensity decays from temporally binned data. We compare Pseudo-FLIM to FLIM bi-exponential and phasor analyses of synthetic melanin, melanocytes/keratinocytes coculture and in vivo human skin. Using parameters of global 3D epidermal melanin density and z-epidermal distribution profile, we provide first insights into the in vivo knowledge of 3D melanin modulations with constitutive pigmentation versus ethnicity, with seasonality over 1 year and with topical application of retinoic acid or retinol on human skin. Applications of Pseudo-FLIM based melanin detection encompass physiological, pathological, or environmental factors-induced pigmentation modulations up to whitening, anti-photoaging, or photoprotection products evaluation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pigmentación de la Piel / Imagenología Tridimensional / Microscopía de Fluorescencia por Excitación Multifotónica / Epidermis / Melaninas / Melanocitos Tipo de estudio: Prognostic_studies Límite: Adolescent / Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Sci Rep Año: 2022 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pigmentación de la Piel / Imagenología Tridimensional / Microscopía de Fluorescencia por Excitación Multifotónica / Epidermis / Melaninas / Melanocitos Tipo de estudio: Prognostic_studies Límite: Adolescent / Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Sci Rep Año: 2022 Tipo del documento: Article País de afiliación: Francia
...