Radius distraction during volar plating of distal radius fractures may improve distal radioulnar joint stability at minimum 3-year follow-up: a retrospective case series study.
BMC Musculoskelet Disord
; 23(1): 181, 2022 Feb 24.
Article
en En
| MEDLINE
| ID: mdl-35209885
BACKGROUND: The surgical technique of radius distraction for stabilization of distal radioulnar joint (DRUJ) if intraoperative DRUJ instability was found after the fixation of distal radius fracture has been previously described, but this surgical technique lacks clinical and radiographic effect in minimal 3 years follow-up. We therefore evaluated the clinical outcome and radiographic results of radius distraction in minimal 3 years follow-up as long-term evaluation. METHODS: We reviewed the case series of distal radius fracture with concomitant DRUJ instability receiving radius distraction from the senior author over a 5-year period (January 1st, 2013, to June 30th, 2017) retrospectively. Radius distraction during volar plating was performed by moving the volar plate distally via compression screw loosening/fastening to achieve firm endpoint on the dorsopalmar stress test. The evaluations of radiographic, including bone union time and ulnar variance, and clinical outcomes, including grading of DRUJ instability, NRS of wrist pain, DASH score, MMWS score, and range of motion of operated wrist at final follow-up, were performed at clinic as minimum 3-year follow-up; a total 34 patients had been evaluated. RESULTS: At minimal post-operative 36 months follow-up, all cases demonstrated acceptable wrist range of motion with stable DRUJs, low NRS of wrist pain (0.6, SD 0.7), and satisfactory DASH score (mean 9.1, SD 6.2) and MMWS score (mean 87, SD 10). There were no cases suffering from nonunion of distal radius. The mean ulnar variance of injured wrist and uninjured wrist were -1.2 mm and 0.2 mm, respectively (SD 1.0 and 0.6) with significant statistical difference. CONCLUSIONS: Radius distraction during volar fixation of distal radius fracture should be considered if DRUJ instability was found by the dorsopalmar stress test intraoperatively, and the long-term DRUJ stability could be achieved by maintenance of normal-to-negative ulnar variance, with decreased wrist pain and satisfactory function outcome. LEVEL OF EVIDENCE: Therapeutic Level IV.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Fracturas del Radio
Tipo de estudio:
Observational_studies
/
Risk_factors_studies
Límite:
Humans
Idioma:
En
Revista:
BMC Musculoskelet Disord
Asunto de la revista:
FISIOLOGIA
/
ORTOPEDIA
Año:
2022
Tipo del documento:
Article
País de afiliación:
Taiwán