Novel Technique for Percutaneous Reduction of Displaced LCII Pelvic Ring Injury: A Case Report.
Chen, Michael J; Kleweno, Conor P; Firoozabadi, Reza.
Afiliación
  • Chen MJ; Department of Orthopaedic Surgery, Harborview Medical Center, Seattle, Washington.
JBJS Case Connect ; 12(1)2022 03 23.
Article en En | MEDLINE | ID: mdl-35320132
ABSTRACT
CASE We present a case report of an elderly patient with a displaced lateral compression type II pelvic ring injury and describe a novel technique for maintaining a percutaneously obtained reduction during percutaneous fixation using a supra-acetabular Schantz pin attached to a mechanical limb positioner.

CONCLUSION:

The mechanical limb positioner used allows the surgeon to hold a multidirectionally obtained reduction of the hemipelvis with ease.