Your browser doesn't support javascript.
loading
Transcatheter Versus Surgical Valve Replacement: A 24-months Propensity-matched Analysis of the SILCARD Registry.
Wilczek, Krzysztof; Hawranek, Michal; Wojakowski, Wojciech; Chodór, Piotr; Zembala, Michal; Buszman, Pawel; Bochenek, Andrzej; Deja, Marek; Dyrbus, Maciej; Ciesla, Daniel; Kalarus, Zbigniew; Gasior, Mariusz; Zembala, Marian.
Afiliación
  • Wilczek K; Department of Cardiology, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Katowice, Silesian Centre for Heart Disease in Zabrze, Poland.
  • Hawranek M; Department of Cardiology, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Katowice, Silesian Centre for Heart Disease in Zabrze, Poland.
  • Wojakowski W; Department Of Cardiology And Structural Heart Diseases, 3rd Division Of Cardiology, Medical University Of Silesia, Katowice, Poland.
  • Chodór P; Department Of Cardiology, Congenital Heart Diseases And Electrotherapy, Silesian Centre For Heart Disease In Zabrze, Medical University Of Silesia, Katowice, Poland.
  • Zembala M; Department Of Cardiac, Vascular And Endovascular Surgery And Transplantology, Medical University Of Silesia, Katowice, Poland, Silesian Centre For Heart Disease In Zabrze, Poland.
  • Buszman P; American Heart Of Poland, Katowice, Poland.
  • Bochenek A; American Heart Of Poland, Katowice, Poland.
  • Deja M; Department Of Cardiac Surgery, Medical University Of Silesia, Katowice, Poland.
  • Dyrbus M; Student Scientific Society, 3rd Department Of Cardiology, School Of Medical Sciences In Zabrze, Medical University Of Silesia, Katowice, Poland.
  • Ciesla D; Department of Cardiology, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Katowice, Silesian Centre for Heart Disease in Zabrze, Poland.
  • Kalarus Z; Department Of Cardiology, Congenital Heart Diseases And Electrotherapy, Silesian Centre For Heart Disease In Zabrze, Medical University Of Silesia, Katowice, Poland.
  • Gasior M; Department of Cardiology, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Katowice, Silesian Centre for Heart Disease in Zabrze, Poland.
  • Zembala M; Department Of Cardiac, Vascular And Endovascular Surgery And Transplantology, Medical University Of Silesia, Katowice, Poland, Silesian Centre For Heart Disease In Zabrze, Poland.
Anatol J Cardiol ; 26(3): 172-179, 2022 Mar.
Article en En | MEDLINE | ID: mdl-35346903
BACKGROUND: Data concerning the comparison between transcatheter aortic valve implantation and surgical aortic valve replacement in a real-world setting are scarce and in Central and Eastern Europe no such data exist. In this study, we aimed at analyzing retrospectively the characteristics and outcome of patients with aortic stenosis treated either with surgical aortic valve replacement or transcatheter aortic valve implantation between 2006 and 2016 in the Silesian Province, Poland in a representative real-world cohort. METHODS: In the Silesian Cardiovascular Database we retrospectively identified 5186 patients who received either transcatheter aortic valve implantation or surgical aortic valve replacement in 1 of 3 tertiary cardiovascular centers. Baseline characteristics, including relevant clinical history, and outcomes were compared before and after propensity-score matching of both groups, with 348 pairs of patients constituting the propensity-matched study cohort. The primary end-point was 24-month all-cause mortality. RESULTS: Preoperative characteristics of propensity-matched groups were similar. There was no difference between transcatheter aortic valve implantation and surgical aortic valve replacement groups with respect to the death rate at 2 years (19.9% vs. 15.6%; P =.479). In the transcatheter aortic valve implantation group, cardiac resynchronization therapy devices were more frequently implanted after the procedure (3.7% vs. 0.0, P <.001). The groups had similar rates of myocardial infarction, stroke, and re-hospitalization. Hospital stay in the matched groups was shorter after transcatheter aortic valve implantation: 14.1 versus 15.7 days (P <.001). CONCLUSIONS: At 24 months, transcatheter aortic valve implantation patients had similar outcomes as surgical aortic valve replacement except for a higher rate of cardiac resynchronization therapy device implantation and shorter hospital stay.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Instrumentos Quirúrgicos Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Anatol J Cardiol Año: 2022 Tipo del documento: Article País de afiliación: Polonia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Instrumentos Quirúrgicos Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Anatol J Cardiol Año: 2022 Tipo del documento: Article País de afiliación: Polonia
...