Your browser doesn't support javascript.
loading
Characterizing the short-latency evoked response to intracortical microstimulation across a multi-electrode array.
Sombeck, Joseph T; Heye, Juliet; Kumaravelu, Karthik; Goetz, Stefan M; Peterchev, Angel V; Grill, Warren M; Bensmaia, Sliman; Miller, Lee E.
Afiliación
  • Sombeck JT; Department of Biomedical Engineering, Northwestern University, Evanston, IL, United States of America.
  • Heye J; Department of Neuroscience, Northwestern University, Chicago, IL, United States of America.
  • Kumaravelu K; Department of Biomedical Engineering, Duke University, Durham, NC, United States of America.
  • Goetz SM; Department of Electrical and Computer Engineering, Duke University, Durham, NC, United States of America.
  • Peterchev AV; Department of Neurosurgery, Duke University, Durham, NC, United States of America.
  • Grill WM; Department of Psychiatry and Behavioral Sciences, Duke University, Durham, NC, United States of America.
  • Bensmaia S; Duke Institute for Brain Sciences, Duke University, Durham, NC, United States of America.
  • Miller LE; Department of Engineering, University of Cambridge, Cambridge, United Kingdom.
J Neural Eng ; 19(2)2022 04 20.
Article en En | MEDLINE | ID: mdl-35378515
ABSTRACT
Objective.Persons with tetraplegia can use brain-machine interfaces to make visually guided reaches with robotic arms. Without somatosensory feedback, these movements will likely be slow and imprecise, like those of persons who retain movement but have lost proprioception. Intracortical microstimulation (ICMS) has promise for providing artificial somatosensory feedback. ICMS that mimics naturally occurring neural activity, may allow afferent interfaces that are more informative and easier to learn than stimulation evoking unnaturalistic activity. To develop such biomimetic stimulation patterns, it is important to characterize the responses of neurons to ICMS.Approach.Using a Utah multi-electrode array, we recorded activity evoked by both single pulses and trains of ICMS at a wide range of amplitudes and frequencies in two rhesus macaques. As the electrical artifact caused by ICMS typically prevents recording for many milliseconds, we deployed a custom rapid-recovery amplifier with nonlinear gain to limit signal saturation on the stimulated electrode. Across all electrodes after stimulation, we removed the remaining slow return to baseline with acausal high-pass filtering of time-reversed recordings.Main results.After single pulses of stimulation, we recorded what was likely transsynaptically-evoked activity even on the stimulated electrode as early as ∼0.7 ms. This was immediately followed by suppressed neural activity lasting 10-150 ms. After trains, this long-lasting inhibition was replaced by increased firing rates for ∼100 ms. During long trains, the evoked response on the stimulated electrode decayed rapidly while the response was maintained on non-stimulated channels.Significance.The detailed description of the spatial and temporal response to ICMS can be used to better interpret results from experiments that probe circuit connectivity or function of cortical areas. These results can also contribute to the design of stimulation patterns to improve afferent interfaces for artificial sensory feedback.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Corteza Somatosensorial Límite: Animals Idioma: En Revista: J Neural Eng Asunto de la revista: NEUROLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Corteza Somatosensorial Límite: Animals Idioma: En Revista: J Neural Eng Asunto de la revista: NEUROLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos
...