Your browser doesn't support javascript.
loading
Reliability and Validity of the Athletic Shoulder (ASH) Test Performed Using Portable Isometric-Based Strength Training Device.
Królikowska, Aleksandra; Mika, Anna; Plaskota, Bartosz; Daszkiewicz, Maciej; Kentel, Monika; Kolcz, Anna; Kentel, Maciej; Prill, Robert; Diakowska, Dorota; Reichert, Pawel; Stolarczyk, Artur; Oleksy, Lukasz.
Afiliación
  • Królikowska A; Ergonomics and Biomedical Monitoring Laboratory, Department of Physiotherapy, Faculty of Health Sciences, Wroclaw Medical University, 50-367 Wroclaw, Poland.
  • Mika A; Institute of Clinical Rehabilitation, University of Physical Education in Krakow, 31-571 Krakow, Poland.
  • Plaskota B; Ergonomics and Biomedical Monitoring Laboratory, Department of Physiotherapy, Faculty of Health Sciences, Wroclaw Medical University, 50-367 Wroclaw, Poland.
  • Daszkiewicz M; Ergonomics and Biomedical Monitoring Laboratory, Department of Physiotherapy, Faculty of Health Sciences, Wroclaw Medical University, 50-367 Wroclaw, Poland.
  • Kentel M; eMKaMED Medical Center, 53-110 Wroclaw, Poland.
  • Kolcz A; Ergonomics and Biomedical Monitoring Laboratory, Department of Physiotherapy, Faculty of Health Sciences, Wroclaw Medical University, 50-367 Wroclaw, Poland.
  • Kentel M; eMKaMED Medical Center, 53-110 Wroclaw, Poland.
  • Prill R; Center of Orthopaedics and Traumatology, Brandenburg Medical School, University Hospital Brandenburg/Havel, 14770 Brandenburg, Germany.
  • Diakowska D; Department of Basic Sciences, Faculty of Health Sciences, Wroclaw Medical University, 50-367 Wroclaw, Poland.
  • Reichert P; Department of Trauma Surgery, Faculty of Medicine, Wroclaw Medical University, 50-367 Wroclaw, Poland.
  • Stolarczyk A; Orthopaedic and Rehabilitation Department, Medical Faculty, Medical University of Warsaw, 02-091 Warsaw, Poland.
  • Oleksy L; Orthopaedic and Rehabilitation Department, Medical Faculty, Medical University of Warsaw, 02-091 Warsaw, Poland.
Biology (Basel) ; 11(4)2022 Apr 11.
Article en En | MEDLINE | ID: mdl-35453777
ABSTRACT
The Athletic Shoulder (ASH) test was introduced as a tool for quantifying the ability to produce and transfer force across the shoulder girdle. Whether using the portable isometric-based strength training device Active5™ is a reliable alternative to a gold standard force plate for ASH testing purposes remains unknown; therefore, the present study determined the reliability and validity of Active5™ usage in the ASH test compared to force plates. Fifty-one healthy participants performed the ASH test using Active5™ and K-Force plates in three separate sessions. The maximal force was measured bilaterally in a prone position at three shoulder abduction angles, precisely at 180°, 135°, and 90°. The first rater carried out the first and third sessions, spaced at a one-week interval. A second rater performed the second session. The reliability was assessed using the intraclass correlation coefficient (ICC). The linear Pearson's correlation coefficient (r) calculation was used to determine the relationship between ASH test results using the two devices. The ICC = 0.77-0.99 result indicated good to excellent reliability for Active5™ usage. A high to a very high correlation between the two devices at 180° and 90° was noted (r = 0.75-0.95). This data supports the isometric-based strength training device Active5™ as a reliable and valid tool for ASH test performance.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Biology (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Polonia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Biology (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Polonia
...