Your browser doesn't support javascript.
loading
Assessing the influence of the menstrual cycle on APT CEST-MRI in the human breast.
Loi, Lisa; Goerke, Steffen; Zimmermann, Ferdinand; Korzowski, Andreas; Meissner, Jan-Eric; Breitling, Johannes; Schott, Sarah; Bachert, Peter; Ladd, Mark E; Schlemmer, Heinz-Peter; Bickelhaupt, Sebastian; Paech, Daniel.
Afiliación
  • Loi L; German Cancer Research Center, Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Faculty of Medicine, University of Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany.
  • Goerke S; German Cancer Research Center, Department of Medical Physics in Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
  • Zimmermann F; German Cancer Research Center, Department of Medical Physics in Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
  • Korzowski A; German Cancer Research Center, Department of Medical Physics in Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
  • Meissner JE; German Cancer Research Center, Department of Medical Physics in Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
  • Breitling J; German Cancer Research Center, Department of Medical Physics in Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
  • Schott S; University Hospital Heidelberg, Department of Gynecology and Obstetrics, Im Neuenheimer Feld 440, 69120 Heidelberg, Germany.
  • Bachert P; German Cancer Research Center, Department of Medical Physics in Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Faculty of Physics and Astronomy, University of Heidelberg, Im Neuenheimer Feld 226, 69120 Heidelberg, Germany.
  • Ladd ME; Faculty of Medicine, University of Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany; German Cancer Research Center, Department of Medical Physics in Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Faculty of Physics and Astronomy, University of Heidelberg, Im Neuenheimer
  • Schlemmer HP; German Cancer Research Center, Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Faculty of Medicine, University of Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany.
  • Bickelhaupt S; German Cancer Research Center, Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; German Cancer Research Center, Junior Group Medical Imaging and Radiology - Cancer Prevention, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
  • Paech D; German Cancer Research Center, Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany. Electronic address: d.paech@dkfz.de.
Magn Reson Imaging ; 91: 24-31, 2022 09.
Article en En | MEDLINE | ID: mdl-35550841
ABSTRACT

PURPOSE:

In fibroglandular breast tissue, conventional dynamic contrast-enhanced MR-mammography is known to be affected by water content changes during the menstrual cycle. Likewise, amide proton transfer (APT) chemical exchange saturation transfer (CEST)-MRI might be inherently prone to the menstrual cycle, as CEST signals are indirectly detected via the water signal. The purpose of this study was to investigate the influence of the menstrual cycle on APT CEST-MRI in fibroglandular breast tissue.

METHOD:

Ten healthy premenopausal women (19-34 years) were included in this IRB approved prospective study and examined twice during their menstrual cycle. Examination one and two were performed during the first half (day 2-8) and the second half (day 15-21) of the menstrual cycle, respectively. As a reference for the APT signal in malignant breast tumor tissue, previously reported data of nine breast cancer patients were included in this study. CEST-MRI (B1 = 0.7µT) was performed on a 7 T whole-body scanner followed by a multi-Lorentzian fit analysis. The APT signal was corrected for B0/B1-field inhomogeneities, fat signal contribution, and relaxation effects of the water signal and evaluated in the fibroglandular breast tissue. Intra-individual APT signal differences between examination one and two were compared using the Wilcoxon signed-rank test. The level of significance was set at p < 0.05.

RESULTS:

The APT signal showed no significant difference in the fibroglandular breast tissue of healthy premenopausal volunteers throughout the menstrual cycle (p = 1.00) (examination 1 vs. examination 2 mean and standard deviation = 3.24 ± 0.68%Hz vs. 3.30 ± 0.73%Hz, median and IQR = 3.36%Hz and 0.87%Hz vs. 3.38%Hz and 0.71%Hz).

CONCLUSION:

The present study provides an important basis for the clinical application of APT CEST-MRI as an additional contrast mechanism in MR-mammography, as menstrual cycle-related APT signal fluctuations seem to be negligible compared to the APT signal increase in breast cancer tissue.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Protones / Neoplasias de la Mama Tipo de estudio: Observational_studies Límite: Female / Humans Idioma: En Revista: Magn Reson Imaging Año: 2022 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Protones / Neoplasias de la Mama Tipo de estudio: Observational_studies Límite: Female / Humans Idioma: En Revista: Magn Reson Imaging Año: 2022 Tipo del documento: Article País de afiliación: Alemania
...