Minimed Medtronic 780G optimizes glucose control in patients with type 1 diabetes mellitus.
Pintaudi, Basilio; Gironi, Ilaria; Nicosia, Riccardo; Meneghini, Elena; Disoteo, Olga; Mion, Elena; Bertuzzi, Federico.
Afiliación
  • Pintaudi B; SC Diabetologia, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
  • Gironi I; SC Diabetologia, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
  • Nicosia R; SC Diabetologia, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
  • Meneghini E; SC Diabetologia, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
  • Disoteo O; SC Diabetologia, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
  • Mion E; SC Diabetologia, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
  • Bertuzzi F; SC Diabetologia, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy. Electronic address: federico.bertuzzi@ospedaleniguarda.it.
Nutr Metab Cardiovasc Dis ; 32(7): 1719-1724, 2022 07.
Article en En | MEDLINE | ID: mdl-35599092
BACKGROUND AND AIMS: The new advanced hybrid closed loop insulin infusion systems have the potential to significantly improve glycaemic control. The aim of this study was to evaluate the effectiveness of the Minimed 780G system in 59 patients with type 1 diabetes. METHODS AND RESULTS: Glucose control obtained by using the system in automatic mode at 1-2 months of activation, at 2-4 months, at 4-6 months, and beyond 6 month was compared with those obtained with the system in manual mode. A significant improvement in time-in-range and in time-above-range throughout the follow-up was observed, as well as a significant reduction in time-below-range (<54 mg/dl) after 6 months, a significant reduction of the glucose variability and of HbA1c. After switching the mode, all target percentages lied on the average within the recommended ranges by literature consensus and no severe hypoglycemia nor ketoacidosis episodes were recorded. CONCLUSION: The Minimed 780G allowed a rapid and progressive improvement of the overall glucose control.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 / 2_ODS3 Problema de salud: 1_doencas_nao_transmissiveis / 2_muertes_prematuras_enfermedades_notrasmisibles Asunto principal: Diabetes Mellitus Tipo 1 Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Nutr Metab Cardiovasc Dis Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / CIENCIAS DA NUTRICAO / METABOLISMO Año: 2022 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 / 2_ODS3 Problema de salud: 1_doencas_nao_transmissiveis / 2_muertes_prematuras_enfermedades_notrasmisibles Asunto principal: Diabetes Mellitus Tipo 1 Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Nutr Metab Cardiovasc Dis Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / CIENCIAS DA NUTRICAO / METABOLISMO Año: 2022 Tipo del documento: Article País de afiliación: Italia
...