Your browser doesn't support javascript.
loading
Comparison of Barrett Toric Calculations Using Measured and Predicted Posterior Corneal Astigmatism in Cataract Surgery Patients.
Lukewich, Mark K; Murtaza, Fahmeeda; Somani, Sohel; Tam, Eric S; Chiu, Hannah H.
Afiliación
  • Lukewich MK; Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.
  • Murtaza F; Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.
  • Somani S; William Osler Health System, Brampton, Ontario, Canada.
  • Tam ES; Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada.
  • Chiu HH; Uptown Eye Specialists, Vaughan, Ontario, Canada.
Clin Ophthalmol ; 16: 1739-1751, 2022.
Article en En | MEDLINE | ID: mdl-35673350
Aim: To compare residual astigmatism prediction errors across Barrett toric calculations using predicted posterior corneal astigmatism (PCA) and PCA measured using the IOL Master 700 with total keratometry (IOLM). Methods: A retrospective cohort study was undertaken on patients with corneal astigmatism and no other ocular comorbidities that underwent uneventful refractive femtosecond laser-assisted cataract surgery with toric IOL implantation between May 2019 and November 2019. Toric calculations were performed using the Barrett toric calculator and the following values: predicted PCA with anterior corneal measurements from Pentacam, IOLM standard keratometry (SK), OPD scan, and median measurements from these devices; predicted PCA with IOLM total keratometry (TK); and measured PCA with IOLM SK or IOLM TK. Residual astigmatism prediction error was calculated for each device and method of calculation at postoperative month 1 and 3 using the astigmatism double angle plot tool. Results: A total of 24 eyes, 10 with-the-rule (WTR), 10 against-the-rule (ATR) and 4 oblique astigmatism, from 24 patients were included in this study. PCA ranged from 0.00 to 0.67 D with a mean of 0.24 ± 0.15 D in all eyes. PCA was significantly greater in WTR eyes (0.32 D) compared to ATR eyes (0.16 D; p < 0.05). In ATR eyes, calculations made using IOLM SK and measured PCA had significantly lower total corneal astigmatism and toric IOL cylinder power compared to calculations made using Pentacam and IOLM TK (p < 0.05). No significant difference in mean absolute or centroid residual astigmatism prediction error was observed across devices or calculation methods. The percentage of eyes with absolute astigmatism prediction errors ≤0.5 D was not significantly different across groups. Conclusion: Barrett toric calculations using predicted PCA and PCA measured using IOLM produced comparable residual astigmatism prediction errors. The incorporation of median measurements did not significantly impact calculation accuracy.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Clin Ophthalmol Año: 2022 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Clin Ophthalmol Año: 2022 Tipo del documento: Article País de afiliación: Canadá
...