Your browser doesn't support javascript.
loading
Dual-color quantum dot-loaded nanoparticles based lateral flow biosensor for the simultaneous detection of gastric cancer markers in a single test line.
Cao, Yue; Chen, Zhenhua; Li, Xijiu; Li, Zhaoyue; Lin, Guanfeng; Liu, Tiancai; Wu, Yingsong.
Afiliación
  • Cao Y; Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China.
  • Chen Z; Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China; Department of Laboratory Medicine, Guangzhou First People's Hospital, School of Medicine, South China University of Technology, Guangzhou, 510180, China.
  • Li X; Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China.
  • Li Z; Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China.
  • Lin G; Experimental Center of Teaching and Scientific Research, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China.
  • Liu T; Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China.
  • Wu Y; Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China. Electronic address: wg@smu.edu.cn.
Anal Chim Acta ; 1218: 339998, 2022 Jul 25.
Article en En | MEDLINE | ID: mdl-35701042
A dual-color quantum dots-loaded nanoparticles (QPs) based lateral flow biosensor with single test line has been developed. Red and green emitted QPs were conjugated with antibodies and served as detecting probes in assays respectively, while the mixture of various antibodies were immobilized on nitrocellulose membranes as one detection line. Benefit from eliminating the heterogeneity caused by different position on the membrane, current biosensor achieved higher accuracy comparing with prevalent multi-lines or multi-strips lateral flow systems, which is of great significance for analyzing ratio-related diagnostics. The capability and reliability of the multiplex biosensor are also demonstrated by utilizing pepsinogen I (PG I) and pepsinogen II (PG II) as the model analytes. Under the optimal conditions, quantitative detection was achieved with ultra-low limits of detection at 6.9 pM (0.29 ng mL-1, PG I) and 15.7 pM (0.66 ng mL-1, PG II) respectively. The spectra crosstalk was negligible and no apparent cross-reaction was found in simultaneous detection. Furthermore, a good linear correlation of the QPs based lateral flow biosensor and commercial time-resolved fluoroimmunoassay was obtained in the detection of clinical samples, indicating the high reliability of the proposed biosensor.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Gástricas / Técnicas Biosensibles / Puntos Cuánticos / Nanopartículas Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Anal Chim Acta Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Gástricas / Técnicas Biosensibles / Puntos Cuánticos / Nanopartículas Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Anal Chim Acta Año: 2022 Tipo del documento: Article País de afiliación: China
...