Your browser doesn't support javascript.
loading
Quantitative Three-Dimensional Computed Tomography Measurements Provide a Precise Diagnosis of Fractures of the Mandibular Condylar Process.
Batbayar, Enkh-Orchlon; Assink, Nick; Kraeima, Joep; Meesters, Anne M L; Bos, Ruud R M; Vissink, Arjan; Witjes, Max J H; van Minnen, Baucke.
Afiliación
  • Batbayar EO; Department of Oral and Maxillofacial Surgery, School of Dentistry, Mongolian National University of Medical Sciences, Zorig Street, Ulaanbaatar 14210, Mongolia.
  • Assink N; Department of Surgery, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
  • Kraeima J; 3D Lab, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
  • Meesters AML; 3D Lab, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
  • Bos RRM; Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
  • Vissink A; Department of Surgery, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
  • Witjes MJH; 3D Lab, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
  • van Minnen B; Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
J Pers Med ; 12(8)2022 Jul 27.
Article en En | MEDLINE | ID: mdl-36013174
ABSTRACT
As 2D quantitative measurements are often insufficient, a standardized 3D quantitative measurement method was developed to analyze mandibular condylar fractures, and correlate the results with the mandibular condylar fracture classifications of Loukota and Spiessl and Schroll and clinical parameters. Thirty-two patients with a unilateral mandibular condylar fracture were evaluated using OPT, 2D (CB)CT images, and 3D imaging to measure the extent of the fractures. The maximum mouth opening (MMO) was measured. Ramus height loss could be measured only in OPT, but not in 2D CT images. The Intraclass Correlation Coefficient was excellent in the 3D measurements. In the Loukota classification, condylar neck fractures had the largest median 3D displacement and the highest rotations of the fracture fragments. The largest fracture volume was observed in base fractures. According to the Spiessl and Schroll classification, type V fractures had the largest median 3D displacement and the highest rotation in the X-axis and Z-axis. Type I fractures had the largest fracture volume. We found a moderate negative correlation between MMO and 3D displacement and rotation on Z-axis. The 2D quantitative analysis of condylar fractures is limited, imprecise, and not reproducible, while quantitative 3D measurements provide extensive, precise, objective, and reproducible information.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Pers Med Año: 2022 Tipo del documento: Article País de afiliación: Mongolia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Pers Med Año: 2022 Tipo del documento: Article País de afiliación: Mongolia
...