Your browser doesn't support javascript.
loading
Discordance in tests used to detect inhibition of the P2Y12 receptor in patients undergoing interventional neuroradiology procedures.
Gegri, Mansour; Cheves, Tracey A; Anderson, Matthew N; McTaggart, Ryan; Sweeney, Joseph D.
Afiliación
  • Gegri M; Departments of Coagulation and Transfusion Medicine, Rhode Island Hospital, Providence, RI, USA.
  • Cheves TA; Departments of Coagulation and Transfusion Medicine, Rhode Island Hospital, Providence, RI, USA.
  • Anderson MN; Departments of Neurosurgery, Warren Alpert School of Medicine at Brown University, Rhode Island Hospital, Providence, RI, USA.
  • McTaggart R; Departments of Diagnostic Imaging, Rhode Island Hospital, Providence, RI, USA.
  • Sweeney JD; Departments of Neurology, Rhode Island Hospital, Providence, RI, USA.
Interv Neuroradiol ; 29(6): 655-664, 2023 Dec.
Article en En | MEDLINE | ID: mdl-36039509
BACKGROUND: Clopidogrel is an inhibitor of the P2Y12 platelet receptor but testing to demonstrate a drug effect is controversial since there are often discordant results between different tests methods. METHODS: Samples from patients taking clopidogrel prior to intracranial flow-diversion procedures were tested using light transmission aggregometry (LTA), whole blood impedance aggregometry (WBIA) and the VerifyNow device (VND). Samples were classified as concordant if all test results were either responsive (inhibition) or resistant. Discordant results were separated using the VND into those with a responsive versus a resistant test result. RESULTS: Samples from 96 patients were studied. Concordance for all three tests was seen in 53/96 (55%) of samples, of which 41 (43%) were responsive and 12 (12%) were resistant. Discordance was observed in 43 samples (45%), 37 (28%) of which were caused by responsive VND and either a resistant WBIA or LTA and 6 (7%) of which were caused by a resistant VND but a responsive test result using either WBIA or LTA. These two discordant groups differed in both platelet count and hematocrit, but no such difference was present between the two concordant groups. CONCLUSION: Discordance in P2Y12 inhibition testing may be partly explained by sample platelet count and hematocrit.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ticlopidina / Inhibidores de Agregación Plaquetaria Límite: Humans Idioma: En Revista: Interv Neuroradiol Asunto de la revista: NEUROLOGIA / RADIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ticlopidina / Inhibidores de Agregación Plaquetaria Límite: Humans Idioma: En Revista: Interv Neuroradiol Asunto de la revista: NEUROLOGIA / RADIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos
...