Your browser doesn't support javascript.
loading
Occult endoleaks revealed during open conversions after endovascular aortic aneurysm repair in a multicenter experience.
Perini, Paolo; Gargiulo, Mauro; Silingardi, Roberto; Bonardelli, Stefano; Bellosta, Raffaello; Franchin, Marco; Michelagnoli, Stefano; Ferrari, Mauro; Turicchia, Giorgio U; Freyrie, Antonio.
Afiliación
  • Perini P; Unit of Vascular Surgery, Department of Medicine and Surgery, University of Parma, Parma, Italy - p.perini@live.com.
  • Gargiulo M; Unit of Vascular Surgery, Cardio-Thoracic and Vascular Department, University Hospital of Parma, Parma, Italy - p.perini@live.com.
  • Silingardi R; Unit of Vascular Surgery, Department of Experimental, Diagnostic and Speciality Medicine, University of Bologna, Bologna, Italy.
  • Bonardelli S; Unit of Vascular Surgery, Department of Biomedical Sciences, University of Modena and Reggio Emilia, Modena, Italy.
  • Bellosta R; Vascular Surgery, Department of Clinical and Experimental Sciences, University of Brescia, Brescia, Italy.
  • Franchin M; Vascular Surgery, Department of Surgery, Poliambulanza Foundation Hospital, Brescia, Italy.
  • Michelagnoli S; Vascular Surgery, Department of Medicine and Surgery, University of Insubria School of Medicine, Varese, Italy.
  • Ferrari M; Vascular and Endovascular Surgery, Department of Surgery, USL Toscana Centro, "San Giovanni di Dio" Hospital, Florence, Italy.
  • Turicchia GU; Vascular Surgery, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy.
  • Freyrie A; AUSL Romagna, Department of Vascular Surgery, Cesena Hospital, Forlì-Cesena, Italy.
Int Angiol ; 41(6): 476-482, 2022 Dec.
Article en En | MEDLINE | ID: mdl-36121171
ABSTRACT

BACKGROUND:

An occult endoleak (OE) may be the underlying cause of aneurysm sac expansion after endovascular aneurysm repair (EVAR). The aim of this study is to describe intraoperative findings of OE during surgical endograft explantations.

METHODS:

This is a retrospective, multicenter analysis of all open conversions (OC) after EVAR from 1997 to 2020 in 12 vascular centers. We excluded patients with a preoperative diagnosis of endograft infection, endograft thrombosis, and thoracic-EVAR. An OE was defined as an endoleak revealed during OC not shown on preoperative imaging, which was likely the real cause for sac enlargement. We reported the number of OE, and we described the type of OE in relation to the initial alleged or associated endoleak. A separate analysis of patients with an initial diagnosis of endotension was also performed.

RESULTS:

An OE was found in 32/255 patients (12.5%). In the 78.1% of the cases (25/32) a type II endoleak hid a type I or III endoleak. Endotension was the initial diagnosis of 26/255 patients (10.2%). In 4/26 cases (15.4%), a type I or II OE was revealed. In 5/26 cases (19.2%) an endograft infection was found intraoperatively. In 2/26 cases we found an angiosarcoma. Fifteen cases of endotension (57.7%) remained unexplained.

CONCLUSIONS:

OE represent a not negligible cause of EVAR failure. A type II endoleak associated with sac enlargement may actually conceal a higher-flow endoleak. In most of the cases, the initial diagnosis of endotension remains unexplained. However, endotension sometimes conceals severe underlying pathologies such as infections.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aneurisma de la Aorta Abdominal / Implantación de Prótesis Vascular / Procedimientos Endovasculares Límite: Humans Idioma: En Revista: Int Angiol Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aneurisma de la Aorta Abdominal / Implantación de Prótesis Vascular / Procedimientos Endovasculares Límite: Humans Idioma: En Revista: Int Angiol Año: 2022 Tipo del documento: Article
...